跳至主要内容
临床试验/NCT06218966
NCT06218966尚未招募不适用

Usability of the Intracochlear Catheter INCAT - a Feasibility Study

Sunnybrook Health Sciences Centre2 个研究点 分布在 1 个国家目标入组 24 人开始时间: 2024年1月15日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
24
试验地点
2
主要终点
Impedance

研究概览

简要总结

This is a feasibility study for a inner ear catheter which will be used to apply steroids to the inner ear. It will be used on nearly deaf patients during their surgery, when they receive an implant that will restore the hearing. Treatment with steroids will improve the maintenance of residual hearing, which will be tested during and after the surgery.

详细描述

Study Device: The INCAT is an intracochlear catheter which is eligible in Canada for intracochlear drug delivery.

Summary: 24 patients with moderate to profound hearing loss and indication for cochlear implantation will receive intracochlear treatment with steroids with an intracochlear catheter (INCAT) for hearing preservation prior to insertion of the cochlear implant array. Subjects will be considered for the study if they are 18 years of age or older and demonstrate a CNC word score in quiet of 60% or less in the ear to be implanted. Subjects will be followed for 6 months post-activation of the audio processor.

Primary Objectives: Determination of feasibility of the intracochlear catheter INCAT and hearing preservation of residual hearing thresholds intra-, postoperatively, and long-term.

Secondary Objectives: Assessment of quality of life, tinnitus and development of speech perception with the implant up to one year after implantation.

Study Endpoint: Feasibility of using the INCAT and assessment of hearing preservation of residual hearing thresholds. Impedance field telemetry will help to assess hearing thresholds pre-, peri-, and postinsertion.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults, 18 years of age or older at the time of implantation
  • Moderate to profound hearing loss in the low frequencies and severe to profound hearing
  • Loss in the high frequencies, bilaterally as defined by (see Figure 4A and B below for example audiogram information)
  • Low-frequency pure tone average (PTA - 250, 500, and 1000 Hz) greater than 40 dB
  • High-frequencies not better than 65 decibels (3000 Hz - 8000 Hz)
  • Sensorineural hearing loss, demonstrated by an air-bone gap of less than or equal to 10 dB
  • Limited benefit from appropriately fit hearing aids, defined by consonant-nucleus-consonant (CNC) word score in quiet of 60% or less in the ear to be implanted and 70% or less in the non-implanted ear
  • CNC word score in quiet of greater than or equal to 10% in the ear to be implanted
  • Fluent in English
  • No radiological contraindications
  • Ability to undergo general anesthesia
  • Appropriate motivation and expectation levels
  • Stated willingness to comply with all study procedures for the duration of the study
  • Able to perform subjective hearing tests
  • Able to fill out questionnaires

排除标准

  • Age less than 18 years
  • Not willing to provide informed consent
  • Unable to perform subjective hearing tests
  • Unable to fill out questionnaires
  • Previous unsensitivity to the investigated drug
  • Unable to follow the protocol for any reasons
  • Evidence that hearing loss is retrocochlear in origin
  • Active middle ear infection
  • Skin or scalp condition precluding use of external audio processor
  • Suspected cognitive impairment or organic brain dysfunction
  • History of prior use of a hearing implant

结局指标

主要结局

Impedance

时间窗: 12 months

Impedance testing for all electrodes

speech audiometry

时间窗: 12 months

CNC, AzBio, HINT

Pure tone average with air and bone conduction

时间窗: 12 Months

air and bone conduction of the frequencies 0.25, 0.5, 1, 2, 4, 6, 8 kHz

ECochG

时间窗: 12 months

electrocochleargraphy

ECAPs

时间窗: 12 months

electrically evoked compound action potential testing for all electrodes

次要结局

  • Tinnitus(12 Months)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验