跳至主要内容
临床试验/NCT03551353
NCT03551353Unknown不适用

Checkout Procedure Before Airway Practices To Provide Clinical Practice With Video Based Feedback

Kocaeli Derince Education and Research Hospital0 个研究点目标入组 10 人开始时间: 2018年7月5日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
10
主要终点
Success rates of anesthesia residents after video assisted feedback (VAF) educational method

研究概览

简要总结

Video-assisted feedback (VAF) is an educational method used by educators in various areas of medicine. It is possible to gain technical and non-technical skills for practical applications such as cardiopulmonary resuscitation and surgical procedures . VAF is an objective proof of an individual's performance because by giving feedback it provides non debatable, accurate, real-time data. By allowing awareness on certain issues it helps correcting the mistakes. Studies have shown improvement in clinical skills after VAF

详细描述

Video-assisted feedback (VAF) is an educational method used by educators in various areas of medicine. It is possible to gain technical and non-technical skills for practical applications such as cardiopulmonary resuscitation and surgical procedures . VAF is an objective proof of an individual's performance because by giving feedback it provides non debatable, accurate, real-time data. By allowing awareness on certain issues it helps correcting the mistakes . Studies have shown improvement in clinical skills after VAF .

Inaccurate or incomplete control of anesthesia equipment before use is associated with serious postoperative morbidity and mortality risk. For this reason, a number of control methods have been developed before the anesthesia application. This is one of these methods that checklists are created and repeated in intermittent periods.

American society of anesthesiologists (ASA) published a guideline to improve patient safety in 2008 . This guideline is summarized as mentioned below.

ASA Checklist:

1.Verify Auxiliary Oxygen Cylinder and Self-inflating Manual Ventilation Device are Available & Functioning 2: Verify patient suction is adequate to clear the airway 3: Turn on anesthesia delivery system and confirm that ac power is available 4: Verify availability of required monitors, including alarms. 5: Verify that pressure is adequate on the spare oxygen cylinder mounted on the anesthesia machine 6: Verify that the piped gas pressures are ≥ 50 psig 7: Verify that vaporizers are adequately filled and, if applicable, that the filler ports are tightly closed. 8: Verify that there are no leaks in the gas supply lines between the flowmeters and the common gas outlet 9: Test scavenging system function. 10: Calibrate, or verify calibration of, the oxygen monitor and check the low oxygen alarm.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Other

入排标准

性别
All
接受健康志愿者

入选标准

  • anesthesia residents will be included in this study

排除标准

  • not to work in anesthesia clinic

结局指标

主要结局

Success rates of anesthesia residents after video assisted feedback (VAF) educational method

时间窗: at month two after first measurement for each participant

Researchers will record video of participants during practical application and the video will asses by the checklist that American society of anesthesiologists (ASA) published in 2008 to improve patient safety

次要结局

  • Success rates of anesthesia residents before video assisted feedback (VAF) educational method(on day 1 for each participant)

研究者

发起方
Kocaeli Derince Education and Research Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

tahsin şimşek

principal investigator

Kocaeli Derince Education and Research Hospital

相似试验