Normative Research of Walking Aid Selection in Normal Subjects
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- Force under the stance limb foot
研究概览
简要总结
This study will collect biomedical performance data on walking characteristics in normal, healthy people when walking with walking aids and when walking unaided. Data will be used for independent reporting and for comparison to matched people with pathological conditions. Data collected will including walking ability, balance, force under the feet when walking and muscle strength.
详细描述
Young adults often tolerate the increased energy expenditure, coordination, and stance limb discomfort associated with walking aids for non-weightbearing ambulation. It is not clear how walking aid selection affects stance limb plantar force, walking speed, perceived exertion, and device preference in adults over 50 years of age..
This project is a prospective randomized crossover study using healthy adults, aged over 50 years, with no use of walking aids within 5 years. Participants will walk 200 m under 4 randomized conditions: single non-weightbearing ambulation using crutches, a walker, a wheeled knee walker, and unaided walking. An in-shoe sensor will measure stance limb plantar force, a stopwatch will be used to time each walk, a hand held dynamometer will measure arm muscle strength, perceived exertion will be reported using the BORG CR-10 scale, and device preference will be identified.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Able bodied individuals self reported good health
排除标准
- •recent fractures history of neurologic disease or events.
结局指标
主要结局
Force under the stance limb foot
时间窗: Through study completion, an average of one day. This is a one time assessment comparing differences in the normal force under the foot when the participant walks under 4 walking conditions.
A wireless insole force sensor (LoadSol; Novel Inc) will be fitted in the shoe of the stance foot to measure stance limb plantar force during each walking trial. This force sensor covers the entire plantar surface of the foot and manufacturer's protocol for calibration will be applied for each participant before data is recorded at 100 Hz via Bluetooth connection to an iOS device (ie, an iPad).
次要结局
- Arm strength in newtons(Through study completion an average of one day. This is a one time assessment to correlate strength with force under the stance limb foot with upper extremity strength under the 4 walking conditions.)
- Perceived Exertion(Through study completion, an average of one day. This is a one time assessment to compare perceived exertion when the participant walks under 4 walking conditions.)
- Walking aid preference(Through study completion, an average of one day.)
研究者
Audrey Zucker-Levin
Professor
University of Saskatchewan
