Comparison of Sensimed Triggerfish (TF) 24 Hour IOP Monitoring With Goldmann Applanation Tonometry (GAT) and Perkins Tonometry in Glaucoma Patients
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 12
- 试验地点
- 2
- 主要终点
- Relation of GAT/Perkins with TF in a cross-over regression analysis.
研究概览
简要总结
This prospective, crossover study is designed to correlate SENSIMED Triggerfish® (TF) continuous IOP monitoring with conventional 24 h intraocular pressure profiles in glaucoma patients. There are two control measurements: The GAT/Perkins profile in the same eye in the second night and the GAT/Perkins profile in the same night in the fellow eye. Therefore, each eye serves as test eye and also as control for the second test eye.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient is able to comply with the study procedure
- •Patient must be ≥ 18 years old
- •Diagnosis of primary open angle glaucoma (EGS criteria)
- •Similar behaviour of IOP in both eyes in former IOP profiles
- •Patient has consented to be in the trial and signed informed consent is available before any study related procedures are carried out
- •Visual Acuity of 20/200 or better in both eyes
- •Ability of subject to understand the character and individual consequences of the study
- •For women with childbearing potential, adequate contraception
排除标准
- 未提供
结局指标
主要结局
Relation of GAT/Perkins with TF in a cross-over regression analysis.
时间窗: 48 hours
Correlation of GAT/Perkins values with TF data (mean, min, max, fluctuation)
次要结局
- Correlation of IOP in the test eye (TF) compared to a conventional 24h IOP profile (GAT) the reference eye (same night)(48 hours)
- Correlation of IOP profile (GAT) right versus left eye(48 hours)
- Correlation of IOP profile (TF) right versus left eye(48 hours)
- Correlation of IOP with blood pressure(48 hours)
- Correlation of IOP with heart rate(48 hours)
研究者
Katrin Lorenz
MD
Johannes Gutenberg University Mainz
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Comparison of Sensimed Triggerfish (TF) 24 Hour Monitoring of the Eye in Glaucoma Patients Before and After TrabeculectomyGlaucomaNCT04000828Johannes Gutenberg University Mainz12
已完成
不适用
SENSIMED Triggerfish Discomfort During IOP MonitoringSafety and Tolerability of SENSIMED Triggerfish in Glaucoma PatientsNCT00966108Sensimed AG40
Unknown
不适用
Clinical Application of Sensimed Triggerfish Sensor (TS) With Wireless Signal Transmission for Continuous Intraocular Pressure MeasurementGlaucomaNCT01467453University of Zurich30
终止
4 期
Use of an Ocular Telemetry Sensor in Tafluprost Treated PatientsGlaucomaNCT01263535Sensimed AG15
已完成
不适用
Efficacy of 24-hour Intraocular Pressure Fluctuation Recording With the SENSIMED Triggerfish Contact Lens SensorPrimary Open Angle GlaucomaHealthy SubjectsNCT01390779Sensimed AG33