跳至主要内容
临床试验/NCT03573284
NCT03573284已完成不适用

Evaluating the Efficacy of Fractional Exhaled Nitric Oxide and Impulse Oscillometry in Patients With Cough Variant Asthma

Zhujiang Hospital1 个研究点 分布在 1 个国家目标入组 146 人开始时间: 2018年8月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
146
试验地点
1
主要终点
the value of fractional exhaled nitric oxide(FeNO) in patients with cough variant asthma

研究概览

简要总结

The aim of the research is to evaluate the clinical value of fractional exhaled nitric oxide(FeNO) ,impulse oscillometry(IOS) and mid-expiratory flow (MEF) in patients with cough variant asthma.

详细描述

The present study has the following objectives:

to evaluate the relationship between BHR and mid-expiratory flow, to assess the diagnostic accuracy of fractional exhaled nitric oxide,impulse oscillometry and mid-expiratory flow in CVA with special regard to its discriminating value between CVA and other causes of a chronic cough, to estimate prognostic value of BHR and fractional exhaled nitric oxide (FeNO) count in predicting response to asthma treatment.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • age 18-65 years old. Cough as the sole or predominant symptom lasting for at least 8 weeks, with no radiographic evidence of lung diseases.

排除标准

  • treatment of any oral corticosteroid in the last 4 weeks, and respiratory tract infection within 8 weeks.
  • smoking (min. 6 months) had asthma or other lung diseases, including obliterative bronchiolitis, bronchiectasis,and cystic fibrosis.

结局指标

主要结局

the value of fractional exhaled nitric oxide(FeNO) in patients with cough variant asthma

时间窗: at least 4 weeks of treatment

FENO will be performed by using a hand-held portable machine (NIOX MINO, Aerocrine AB, Solna, Sweden) at a standard flow rate of 50 mL/s, in accordance with ATS/ERS recommendations.

the value of impulse oscillometry(IOS) in patients with cough variant asthma

时间窗: at least 4 weeks of treatment

R5-R20(respiratory resistance)is measure by Jaeger MasterScreen Pulmonary

次要结局

  • the value of forced mid-expiratory flow (MMEF) in patients with cough variant asthma(at least 4 weeks of treatment)
  • the value of BHR and fractional exhaled nitric oxide (FeNO) count in predicting response to asthma treatment(at least 4 weeks of treatment)
  • the relationship between BHR and mid-expiratory flow(at least 4 weeks of treatment)

研究者

发起方
Zhujiang Hospital
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Validity of Fractional Exhaled Nitric Oxide and... | 临床试验