跳至主要内容
临床试验/NCT05972148
NCT05972148已完成不适用

The Accuracy of Intraoral Scanning and Photogrammetry on the Clinical Fit of Long-span Frameworks

William Negreiros2 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2019年8月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
2
主要终点
To investigate the precision of intraoral scanner compared with photogrammetry in performing complete-arch digital implant impressions

研究概览

简要总结

The goal of this cross-over clinical trial is to investigate the precision of digital implant impressions using an intraoral scanner and photogrammetry in obtaining complete-arch implant-supported scans.

The main question[s] it aims to answer are:

  • Is there a difference in precision between intraoral scans and photogrammetry in obtaining digital implant scans?
  • Will arch perimeter and jaw type (maxilla vs. mandible) affect the precision results?

Procedures: At each appointment, participants existing permanent/temporary prosthesis or healing caps were unscrewed and temporarily removed for the period of the consultation appointment.

Scanbodies were screwed into their implants for the duration of the appointment.

They underwent two types of digital implant impression procedures (five times each), including intraoral scan and photogrammetry.

Intraoral and extraoral photography were taken.

At the end of each appointment, the scanbodies were removed, and existing bridge/healing caps were reinserted.

The procedures were not painful or required any form of local anesthetic

Comparison group: Researchers compared the precision of intraoral scanning vs. photogrammetry to see which device provided the best precision outcomes.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Present with a completely edentulous arch with at least four implants
  • Have bone-level implants
  • Intended for restoration with a screw-retained abutment-level fixed implant-supported prosthesis.

排除标准

  • Patients unable to tolerate the digital scans impressions
  • Presented with implants other than bone-level platforms
  • Not intended for restorations with screw-retained abutment-level fixed implant-supported prosthesis
  • Not completely edentulous.

结局指标

主要结局

To investigate the precision of intraoral scanner compared with photogrammetry in performing complete-arch digital implant impressions

时间窗: During procedure [two hours]

次要结局

未报告次要终点

研究者

发起方
William Negreiros
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

William Negreiros

Research Associate

Harvard School of Dental Medicine

研究点 (2)

Loading locations...

相似试验