Synchronized Nasal Intermittent Positive Pressure Ventilation Versus Noninvasive Neurally Adjusted Ventilatory Assist Ventilation in Extremely Premature Infants: a Randomized Crossover Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 14
- 试验地点
- 2
- 主要终点
- Asynchrony index
研究概览
简要总结
The aim of this study is to demonstrate a significant decrease in asynchrony with NIV-NAVA using the Servo n ventilator (Getinge, Sweden), as compared to abdominal triggered (Graseby capsule) synchronized nasal intermittent positive pressure ventilation (sNIPPV) using the Infant Flow CPAP device (Care Fusion, USA).
All of the data obtained can be used to develop a large-scale study aimed at reducing the rate of re-intubation in the study population (pilot study). In fact, the re-intubation criteria for extremely premature children are based on clinical criteria (desaturations, apnea, signs of respiratory control) and paraclinical criteria (FiO2, Potential hydrogen (pH), PCO2).
The results of this pilot study will help to develop an adapted methodology and to calculate a sample size to compare the 2 modes of NIV to the test on a clinical criterion: the rate of re-intubation after extubation, which is classically high in these patients.
详细描述
The use of non-invasive ventilation has significantly reduced morbidity and mortality in premature newborns by reducing the pulmonary lesions caused by invasive ventilation. Currently, variable flow continuous positive airway pressure (CPAP) devices, such as the infant flow® driver, are considered more efficient than constant flow pressure sources. Nasal intermittent positive pressure ventilation, as compared to CPAP, might reduce the extubation failure rate, but has no impact on mortality or bronchopulmonary dysplasia. However, data is lacking on the interest of synchronization and on the effect of the different available interfaces (prongs, masks, cannulas). In addition, the ventilatory characteristics (high respiratory rate and low inspiratory effort) of the premature infant increase the risk of asynchrony between the patient and the ventilator, which is a major cause of poor tolerance for this type of ventilation.
NAVA (neurally adjusted ventilatory assist) is a recent ventilatory mode that offers proportional assistance to respiratory work based on the measured electrical activity of the diaphragm via oesophageal electrodes. It thus allows a regulation of inspiratory pressures and time by the patient him/herself. The physiological effects of NAVA have been primarily described in intubated neonates and studies have shown a significantly improved synchronization and significantly decreased inspiratory pressures in patients ventilated with NAVA compared to intermittent controlled ventilatory support. However, the currently available evidence is limited and no beneficial effect on morbidity or mortality has been identified so far .
There are few studies on noninvasive NAVA (NIV-NAVA) conducted exclusively in neonates, most of which included a limited number of patients. Only one study to date compared NIV-NAVA to another synchronized NIV mode (NIV pressure support) using the Servo-i ventilator. This prospective crossover study found a significant decrease in peak inspiratory pressure (PIP), FiO2, frequency and length of desaturations in the NIV-NAVA group.
Decreased asynchrony has been observed during NIV-NAVA as compared to pressure-support NIV In adult patients and in 6 children hospitalized in the Pediatric ICU (median age 18 months).
In premature neonates, variable flow CPAP is preferentially used. Synchronized intermittent positive pressure can be delivered using a variable flow device and a Graseby abdominal capsule. Since variable flow CPAP is considered the most efficient pressure generator, it is legitimate to compare synchronization performance of the variable flow synchronized nasal intermittent positive pressure ventilation (sNIPPV) to NIV-NAVA. This comparison has never been performed so far, to our knowledge.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 3 Days 至 —(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
Asynchrony index
时间窗: 4 hours
Asynchrony index as previously defined in the literature using the following parameters: Ineffective effort (IE): presence of an inspiratory electromyographic signal not followed by pressurization; Late cycling (LC): a cycle with an inspiratory time greater than twice the patient's neural inspiratory time; Premature cycling (PC): a cycle with an inspiratory time shorter than the the neural inspiratory time; Double triggering (DT): two ventilator-delivered cycles triggered by one neural inspiration; Auto triggering (AT): a cycle delivered by the ventilator in the absence of EAdi signal.
次要结局
- Mean change in electric activity of the diaphragm (Edi)(4 hours)
- Desaturations(4 hours)
- Bradycardia(4 hours)
- Fi02(4 hours)
- Nava level(1 hour)
- Inspiratory pressure during sNIPPV(1 hour)
- Bag-mask ventilation or re-intubation(4 hours)
- transcutaneous PCO2(4 hours)
- Re-intubation within 7 days(7 days)
- Components of the Asynchrony index(4 hours)
- Apnoea(4 hours)
- ComfortNeo score(4 hours)