Patient-specific Finite Element Analysis of Immediate Loading in the Edentulous Maxilla: Comparison of Three Implant Configurations Using Digital Twins.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 1
- 试验地点
- 1
- 主要终点
- Stress distribution in the Maxillary Bone
研究概览
简要总结
Rehabilitation of severely atrophic edentulous maxillae with dental implants pose a significant clinical challenge. Immediate loading in grafted bone is often debated due to concerns about stress distribution and osseointegration. This study aimed to compare stress distribution in the maxilla using three full-arch implant configurations-all-on-four, all-on-six, and quad-zygomatic implants-in a single patient, to determine the safest and most favorable approach for immediate loading in grafted bone. Two CBCT scans from a 64-year-old female patient, before and after bone grafting (allograft with onlay grafting and sinus augmentation), were used to generate three patient-specific finite element models. Each model included the maxilla, implants in the respective configuration, abutments, and a full-arch prosthesis. Von Mises stresses in cortical and cancellous bone, implants, abutments, and prosthesis, as well as maximum bone displacement, were analyzed. Our results demonstrated that the all-on-six configuration provided the most favorable biomechanical outcome, with homogeneous cortical stress distribution, reduced stress in implants and prosthesis, and bone displacement fully compatible with immediate loading in grafted bone. The all-on-four model showed stress peaks at tilted abutments and cantilevers, whereas the quad-zygomatic model distributed implant and abutment stresses efficiently but induced higher cortical bone stresses, still within physiological limits.This patient-specific digital twin study demonstrates that immediate loading in full-arch grafted bone is biomechanically safe and optimal, with the all-on-six configuration providing superior stress distribution. These findings support clinical decision-making for immediate loading protocols and highlight the value of patient-specific FEA in planning complex maxillary rehabilitations.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Retrospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Edentulous maxillae, have had full-arch bone reconstruction
排除标准
- 未提供
结局指标
主要结局
Stress distribution in the Maxillary Bone
时间窗: At inclusion
Finite element analysis (FEA) a numerical simulation method that models how mechanical forces affect anatomical structures. This technique visualizes stress, tension, compression and displacement zones in the maxillary bone. Stress values are expressed in megapascals (MPa) and displacements in microns (μm).
Stress distribution in the Implants
时间窗: At inclusion
Finite element analysis (FEA). This technique visualizes stress, tension, compression and displacement zones in the implant. Stress values are expressed in megapascals (MPa) and displacements in microns (μm).
Stress distribution in the Prosthesis
时间窗: At inclusion
Finite element analysis (FEA). This technique visualizes stress, tension, compression and displacement zones in the prosthesis. Stress values are expressed in megapascals (MPa) and displacements in microns (μm).
次要结局
- Accuracy of the digital model digital twin of real patient(At inclusion)