Respiratory Variations in Diameters of the Inferior Vena Cava and the Internal Jugular Vein to Assess Blood Withdrawal in Patients With Genetic Hemochromatosis
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 27
- 试验地点
- 1
- 主要终点
- blood withdrawal-induced changes in the respiratory variations of the inferior vena cava during a standardized respiratory maneuver (ΔIVCST)
研究概览
简要总结
OBJECTIVES: To investigate whether respiratory variations of the inferior vena cava (ΔIVC) and internal jugular vein (ΔIJV) diameters during standardized breathing (ΔIVCST and ΔIJVST) increase after a therapeutic bleeding in spontaneously breathing and non-obese patients with genetic hemochromatosis.
DESIGN: Prospective, monocentric study in the EFS Nord-de-France blood center.
PATIENTS: Non-obese patients with genetic hemochromatosis undergoing a therapeutic bleeding.
INTERVENTIONS: Ultrasound measures and collected clinical parameters before and after a therapeutic bleeding, during a standardized respiratory maneuver.
MAIN OUTCOME AND MEASURES: The primary endpoint was the ΔIVCST change induced by a 300 to 500ml therapeutic bleeding. It measured the minimal and maximal IVC and IJV diameters during a standardized respiratory maneuver. ΔIVCST and ΔIJVST were calculated as follows: [(maximal diameter - minimal diameter)/maximal diameter].100.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •adult patients of > or equal 18 years
- •genetic hemochromatosis
- •undergoing a therapeutic blood withdrawal
- •health insured
- •non-obese (body mass index <30Kg/m²)
排除标准
- •pregnancy
- •transthoracic echogenicity unsuitable for measuring the inferior vena cava diameters
- •clinical signs of active exhalation
结局指标
主要结局
blood withdrawal-induced changes in the respiratory variations of the inferior vena cava during a standardized respiratory maneuver (ΔIVCST)
时间窗: during a standardized respiratory maneuver, an average 1 hour maximum
The primary endpoint was the ΔIVCST change induced by a 300 to 500ml therapeutic bleeding. The investigators measured the minimal and maximal IVC diameters during a standardized ventilation. ΔIVCST was calculated as follows: \[(maximal diameter - minimal diameter)/maximal diameter\].100.
次要结局
- blood withdrawal-induced changes in the respiratory variations of the internal jugular vein during a standardized respiratory maneuver (ΔIJVST)(during a standardized respiratory maneuver, an average 1 hour maximum)