The RW-Precision-Coupler Clinical Investigation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 5
- 试验地点
- 2
- 主要终点
- Freiburger Monosyllable Test
研究概览
简要总结
The RW-Precision-Coupler Clinical Investigation is prospective, non-randomized, open label, single subjects repeated measures, longitudinal monocentric trial. The primary aim of this pre-market clinical investigation is to evaluate the clinical performance and safety of VSB together with the VSB RWP-Coupler in the treatment of hearing loss. As secondary aims are to evaluate the clinical performance of VSB together with RWP-Coupler by measuring Sound Field audiometry (SF), to evaluate the safety of VSB together with RWP-Coupler by measuring bone conduction (BC) thresholds and collecting and assessing adverse events.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Geographically and physically able to return to the investigational site for scheduled evaluations and follow-up appointments
- •Fluent in the German language
- •Persons of 18 years of age or older
- •Signed and dated informed consent before the start of any study-specific procedure
- •The physician must fully assess the potential risks and benefits for the patient prior to the decision to implant the RW-Precision-Coupler. The physician must exercise medical judgment and consider the patient's complete hospital record (also called medical history)
- •No previous active middle ear implant surgery performed in the implanted ear
- •The following indication for VORP503:
- •For a patient with sensorineural hearing loss, pure-tone air conduction threshold levels at or within the levels listed below:
- •For a patient with conductive or mixed hearing loss, pure tone bone-conduction threshold levels at or within the levels listed below:
- •A patient shall present with an ear anatomy that can facilitate positioning of the FMT in contact with a suitable vibratory structure of the ear.
- •A patient with sensorineural hearing loss shall be a current user of an acoustic hearing aid and have used this aid for at least 4 hours (average) per day for at least 3 months prior to evaluation, or shall not be able to wear or benefit from conventional hearing aids for medical reasons.
- •A patient shall be psychologically and emotionally stable with realistic expectations of the benefits and limitations of the Soundbridge
排除标准
- •Simultaneous participation in another clinical trial (on device or on drug) which would interfere with the results of the study
- •Pregnancy or lactation
- •Contraindication for RWP-Coupler Sizer:
- •if a patient is known to be intolerant of the materials used in the RWP-Coupler.
- •if a patient is known to be intolerant of the materials used in the RWP-Coupler Sizer.
- •in case of a fixed stapes footplate.
- •Contraindication for VORP503:
- •A patient is known to be intolerant of the materials used in the implant (medical grade silicone elastomer, medical grade epoxy and titanium).
- •A patient with retrocochlear, or central auditory disorders.
- •A patient with nonresponsive active ear infection and/or chronic fluid in or about the ear.
- •A patient whose hearing loss has demonstrated an improving and decreasing fluctuation over a two-year period of 15 dB in either direction.
- •A patient with any physical, psychological, or emotional disorder that would interfere with surgery or the ability to perform on test and rehabilitation procedures.
- •A patient with a skin or scalp condition that may preclude attachment of the audio processor with a magnet.
结局指标
主要结局
Freiburger Monosyllable Test
时间窗: 6 months post-operative
Investigate the improvement of unaided pre-activation Word Recognition Scores (WRS) to 6 months post-operation aided WRS with RW-Precision-Coupler
次要结局
未报告次要终点