跳至主要内容
临床试验/NCT01747031
NCT01747031Unknown不适用

Diagnostic Performance of Instantaneous Wave-Free Ratio From Computed Tomography

Shanghai 10th People's Hospital1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2012年12月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
100
试验地点
1
主要终点
Diagnostic Accuracy of iFRCT

研究概览

简要总结

The iFRCT study is a prospective, multicenter study to evaluate the diagnostic performance of iFRCT with the use of ≥64-detector row CT scanners for the detection and exclusion of significant obstructive coronary artery disease, defined by invasive fractiona flow reserve (FFR) as the reference standard.

详细描述

Noninvasive fractional flow reserve (FFR) computed from CT (FFRCT) is a novel method for determining the physiologic significance of coronary artery disease (CAD), and several clinical trials have revealed that the FFRCT has a good correlation with invasive FFR, also use of noninvasive FFRCT plus Computed Tomography (CT ) among stable patients with suspected or known CAD was associated with improved diagnostic accuracy and discrimination vs CT alone for the diagnosis of hemodynamically significant CAD.

The cornerstone of FFR is the linear relationship between pressure and flow under conditions of constant (and minimized) intracoronary resistance, so is FFRCT. Under such conditions, pressure and flow are assumed to be directly proportional, and a decrease in pressure across a stenosis reflects a decrease in blood flow to the dependent myocardium. However, even after administration of potent pharmacologic agents such as adenosine, intracoronary resistance is not static, but instead fluctuates in a phasic pattern throughout the cardiac cycle. In addition, for patients who are allergic to pharmacologic agents or with sever lesions which response little to pharmacologic agents, the measurement of FFR is challenging and the lesion are always underestimated. The ADVISE trial revealed that intracoronary resistance is naturally constant and minimized during the wave-free period. The instantaneous wave-free ratio calculated over this period produces a drug-free index of stenosis severity comparable to FFR. But whether iFR calculated from Computed Tomography(iFRCT) is comparable to FFRCT or FFR, and its diagnostic performance remains unknown. Thus the investigators conduct this trial to assess the diagnostic performance of Instantaneous Wave-Free Ratio for diagnosis of hemodynamically significant coronary stenosis.

Instantaneous Wave-Free Ratio calculated from reconstructed heart model.Wave-intensity analysis identified a wave-free period in which intracoronary resistance at rest is similar in variability and magnitude.The investigators define the resting distal-to-proximal pressure ratio during this period as the instantaneous wave-free ratio (iFR).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
Triple (Participant, Care Provider, Investigator)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Coronary computed tomographic angiography(CCTA) with over 50 percent stenosis in a major coronary artery over 2mm diameter
  • Undergoing clinically indicated invasive coronary angiography with FFR

排除标准

  • A history of CABG surgery
  • Prior percutaneous coronary intervention with suspected instent restenosis
  • Suspicion of or recent acute coronary syndrome
  • Complex congenital heart disease
  • Prior pacemaker or defibrillator
  • Prosthetic heart valve
  • Significant arrhythmia
  • heart rate >100 beats/min
  • systolic blood pressure≤90 mmHg
  • contraindication to beta blockers, nitroglycerin or adenosine
  • Serum creatinine level greater than 1.5 mg per dL
  • Allergy to iodinated contrast
  • Pregnant state
  • Body mass index greater than 35
  • Evidence of active clinical instability or lifethreatening disease
  • Canadian Cardiovascular Society class IV angina
  • nonevaluable CCTA as determined by the CCTA core laboratory
  • Inability to adhere to study procedures

结局指标

主要结局

Diagnostic Accuracy of iFRCT

时间窗: 1 day

Diagnostic accuracy\[Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV)\]\* of CCTA plus iFRCT(instantaneous wave-free ratio calculated in reconstructed heart model) or iFRCT alone to determine presence or absence of at least one hemodynamically (HD)-significant coronary artery stenosis at the subject level using binary outcomes when compared to FFR as the reference standard.\*Sensitivity measures the proportion of actual positives which are correctly identified. Specificity measures the proportion of negatives which are correctly identified;PPV, or precision rate is the proportion of positive test results that are true positives (such as correct diagnoses);NPV is defined as the proportion of subjects with a negative test result who are correctly diagnosed.

次要结局

  • Diagnostic accuracy of iFRCT at the subject level(1 day)
  • Diagnostic accuracy of iFRCT at the vessel level(1 day)
  • FFR Numerical Correlation(1 day)
  • FFRCT Numerical Correlation(1 day)
  • Predicted Post-PCI FFR Measurement(1 day)

研究者

发起方
Shanghai 10th People's Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Ya-Wei Xu

MD FACC

Shanghai 10th People's Hospital

研究点 (1)

Loading locations...

相似试验