Endobiliary Percutaneous Cryobiopsy in Malignant Biliary Obstruction

Brno University Hospital2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2023年6月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
20
试验地点
2
主要终点
Quality of samples collected by endobiliary cryobiopsy and forceps biopsy - weight

研究概览

简要总结

The rationale of the study is to explore the safety and efficacy of percutaneously performed endobiliary cryobiopsy in patiens with histologically unverified biliary stenosis.

详细描述

In patients with malignant biliary stenosis in whom endoscopic retrograde cholangiography (ERCP) is not feasible , percutaneous transhepatic drainage (PTD) is indicated. Biopsy is required for further management of the patient. In patients unsuitable for biopsy under CT or endoscopic guidance, samples can be collected endobiliary by PTD. The biopsy vie PTD can be sampled either at the initial drainage using disposable 5.2F forceps or delayed after 2 or more days using 7.5F endobiliary forceps. An alternative to this procedure is endobiliary sampling by cryobiopsy using 1.1mm, 1.7mm or 2.4mm catheters. To minimize bias, each patient will be sampled both by cryobiopsy and forceps biopsy. The order of cryobiopsy and forceps biopsy will be randomized.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Diagnostic
盲法
Single (Investigator)

盲法说明

Randomization was performed by the Institute of Biostatistics and Analysis of Masaryk University Brno.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • biliary stenosis of unknown etiology
  • unsuccessful or unfeasable ERCP
  • indicated percutaneous transhepatic drainage

排除标准

  • histologically verified biliary stenosis
  • INR ≥ 1,5

结局指标

主要结局

Quality of samples collected by endobiliary cryobiopsy and forceps biopsy - weight

时间窗: up to month 12 or death of the patient

Comparison of weight (in milligrams) of samples collected by endobiliary cryopsy and forceps biopsy. Each sample will be weighed separately and one measurement value will be recorded for each sample.

Sensitivity of biopsy sampling to detect malignancy

时间窗: up to month 12 or death of the patient

Comparison of sensitivity of endobiliary cryobiopsy and forceps biopsy for detection of malignancy.

Quality of samples collected by endobiliary cryobiopsy and forceps biopsy - size

时间窗: up to month 12 or death of the patient

Comparison of the size weight (in millimeters) of samples collected by endobiliary cryopsy and forceps biopsy. Each sample will be weighed in two dimensions on slide.

次要结局

未报告次要终点

研究者

发起方
Brno University Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Tomas Andrasina

Tomáš Andrašina, MD, PhD; Assistant professor, Head of Non-vascular interventions and Computed Tomography of the Department of Radiology and Nuclear Medicine

Brno University Hospital