Advantages of 3D Printing in the Management of Acetabular Fractures Fixed by the Kocher Langenbeck Approach
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 109
- 主要终点
- Quality of fracture reduction
研究概览
简要总结
Background: Acetabular fractures result from violent trauma, and their incidence has been increasing in recent years. The Kocher-Langenbeck surgical approach is used for the internal fixation of displaced fractures of the posterior structures of the acetabulum. The quality of the reduction and the stability of osteosynthesis directly influence the function of the repaired acetabulum. In the surgical management of acetabulum fractures, 3D printing of a bone model is increasingly used during preoperative planning by trauma surgeons worldwide.
Questions: Is there a difference in the surgical time of the Kocher-langenbeck reduction and fixation of the posterior structures of the acetabulum between 3D printing (which allows for shaping of the reconstruction plate prior to surgery) and the conventional technique? Are there any differences in complications between the two techniques? Are there any short-term differences in the functional and radiographic scores between 3D printing and the conventional technique? Methods: 109 consecutive patients who sustained fractures of the acetabulum were screened for inclusion. 43 patient were studied. The first group (G1) consisted of 20 patients who underwent prior molding of the osteosynthesis plate on a 3D-printed model. The second group (G2 or control group) included 23 patients who underwent surgery using the conventional technique. We compared surgical time, intraoperative blood loss, the difference between pre- and postoperative hemoglobin, and the onset of early infection, paralysis of the sciatic nerve, and deep vein thrombosis.
详细描述
This randomized, prospective study included 109 consecutive patients who were treated for fractures of the acetabulum between September 2016 and February 2019 at our institution. This study was approved by the ethics committee at our institution and verbal and written informed consent was obtained from all patients. The final analysis included 43 patients (33 males and 10 females) who underwent the Kocher-Langenbeck approach for the reduction and fixation of the posterior structures of the acetabulum.
The patients were divided into two groups. Group 1 (G1) consisted of 20 patients who underwent preoperative molding of the osteosynthesis plate on a 3D printed model of the pelvis. Group 2 (G2 or control group) included 23 patients who underwent surgery using the conventional technique.
All patients were examined in the outpatient department via clinical and radiographic evaluation at 3, 6, 12, and 24 weeks postoperatively, then every 6 months thereafter. A standard radiographic assessment including three views (AP, iliac oblique, and obturator oblique) and a pelvic CT scan were obtained for all patients at the last follow-up visit. The reductions were classified as one of three types: anatomical (residual displacement <1 mm), imperfect (residual displacement 1 to 3 mm), and poor (residual reduction >3 mm). Clinical outcomes were assessed using the modified Harris Hip score. Bone consolidation was obtained in all cases. Clinical and radiographic results at the last follow-up as well as the minimum follow-up duration were evaluated by one surgeon who did not participate in the surgical management of the patients.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
盲法说明
Clinical and radiographic results at the last follow-up were evaluated by one surgeon who did not participate in the surgical management of the patients
入排标准
- 年龄范围
- 23 Years 至 57 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Fractures of the posterior structures of the acetabulum
- •treatment using the Kocher-Langenbeck approach.
排除标准
- •age over than 60 years
- •treatment approach other than the Kocher-Langenbeck's ( eg orthopedic method)
- •open fractures of the pelvis
- •fractures of the acetabulum older than 3-weeks
- •polytrauma with/or multiple fractures.
- •unavailability for follow-up
- •insufficient clinical and radiographic data.
研究组 & 干预措施
3D printing group
Group 1 (G1) consisted of 20 patients who underwent preoperative molding of the osteosynthesis plate on a 3D printed model of the pelvis. A preoperative scan of the healthy hemi-pelvis was used to create the 3D-printed model for patients in G1 according to the following three-step methodology: 1) A scanographic acquisition of images was performed using a multi-strip scanner in thin sections. These images were recorded as digital images in the standard medical format of digital imaging and communications ; 2) A digital, 3D model of the pelvis in the stereolithography format was created to digitally treat the 2D images. The individualization of the healthy hemi-pelvis, to which a "mirror effect" was applied allowed for the creation of a symmetrical 3D image, as hemi-pelvises are globally symmetrical. 3) A 3D printer was used to create a physical, 3D-printed model of the affected hemi-pelvis using polylactic acid.
干预措施: Fractures of the posterior structures of the acetabulum treated by fixation using the Kocher-Langenbeck approach. (Procedure)
conventional technique group
Group 2 (G2 or control group) included 23 patients who underwent surgery using the conventional technique.The patients in the control group (G2) underwent surgery following the conventional procedure based on radiographic and CT images with 3D reconstructions.
干预措施: Fractures of the posterior structures of the acetabulum treated by fixation using the Kocher-Langenbeck approach. (Procedure)
结局指标
主要结局
Quality of fracture reduction
时间窗: 30 months with minimum of 18 months
CT scan displacement of fracture as one of three: * Anatomical (residual displacement \<1 mm) * Imperfect (residual displacement 1 to 3 mm) * Poor (residual reduction \>3 mm)
radiographic criteria
时间窗: 30 months with minimum of 18 months
Matta scoring system a grade of : * Excellent :indicates a normal appearance of the hip; * Good: mild changes, small osteophytes, moderate (one-millimeter) narrowing of the joint, and minimum sclerosis; a grade of * Fair:intermediate changes, moderate osteophytes, moderate (less than 50 per cent) narrowing of the joint, and moderate sclerosis; and a grade of * Poor: advanced changes, large osteophytes, severe (more than 50 per cent) narrowing of the joint, collapse or wear of the femoral head, and acetabular wear.
Clinical score
时间窗: 30 months with minimum of 18 months
Modified Harris Hip Score includes the pain and function components: The maximum score of 91 is multiplied by 1.1 to give a total score out of 100 Modified Hip Harris score * Excellent: 90-100 * Good: 80-90 * Fair 70-80 * Poor: \<70
次要结局
未报告次要终点
研究者
Mohamed Bouabdellah
MD
University Tunis El Manar