跳至主要内容
临床试验/NCT05766943
NCT05766943招募中不适用

The Efficacy of the Smart Pass Filter to Reduce the Risk for Inappropriate Subcutaneous Implantable Cardioverter-defibrillator Shocks From Myopotential Interference

Medical University of South Carolina2 个研究点 分布在 1 个国家目标入组 71 人开始时间: 2023年11月6日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
71
试验地点
2
主要终点
The incidence of myopotential interference

研究概览

简要总结

This study is enrolling participants who are already implanted with a S-ICD device ( subcutaneous ICD), and are undergoing a routine outpatient clinic follow up appointment to have their S-ICD checked. The aim of the study is to see if a feature in the device can recognize muscle movement and differentiate movement from irregular heart signals. The study involves doing some simple arm exercises while collecting device data, both with this feature turn on and then with it turned off. Participants will be randomized to either have the feature turned on or off initially then it will be programmed the alternative way and the same exercise testing will be repeated. The study will involve just one visit.

详细描述

This study is enrolling participants who are already implanted with a S-ICD device ( subcutaneous ICD), and are undergoing a routine outpatient clinic follow up appointment to have their S-ICD checked. The aim of the study is to see if a feature in the device can recognize muscle movement and differentiate movement from irregular heart signals. The study involves doing some simple arm exercises while collecting device data, both with this feature turn on and then with it turned off. Participants will be randomized to either have the feature turned on or off initially, then it will be programmed the alternative way and the same exercise testing will be repeated. The study will involve just one visit. Following this visit study participation is complete.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least 18 years of age
  • Implanted EMBLEM S-ICD (Model A 209 and Model A 219, Boston Scientific, St Paul, MN, USA)

排除标准

  • Less than 18 years of age
  • Hemodynamically unstable
  • Inability to preform TET due to orthopedic issues or cognitive impairment

研究组 & 干预措施

Smart Pass ON

Active Comparator

Smart Pass filter will be programmed ON in the S-ICD while performing exercise testing.

干预措施: Smart Pass ON (Device)

Smart Pass OFF

Placebo Comparator

Smart Pass filter will be programmed OFF in the S-ICD while performing exercise testing.

干预措施: Smart Pass OFF (Device)

结局指标

主要结局

The incidence of myopotential interference

时间窗: throughout the intervention, approximately 20 minutes

The incidence of myopotential interference, assessed by subcutaneous electrogram annotated "T" marker during the tube exercise test with or without Smart Pass filter

次要结局

  • Incidence of MPI in US participants and Japanese participants(duration of enrollment, approximately 6 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Gold

Professor

Medical University of South Carolina

研究点 (2)

Loading locations...

相似试验