Effort to Reduce Postoperative Brachial Neuropraxia Through Nerve Compression
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 40
- 主要终点
- A change in arterial line wave form and a change in the neuromuscular signal using SSEP or EPAD will be measured and tested with the Pearson correlation coefficient as well as nonparametric Spearman's rank correlation coefficient.
研究概览
简要总结
The purpose of this study is to ultimately prevent injuries to nerves during surgical procedures. Living donor liver transplant or hepatectomy (removal of a piece of the liver) patients will receive an arterial line as standard of care. The arterial line helps monitor blood pressure along with the compression of important vessels during surgery. In addition, research participants will undergo neuromuscular monitoring using Somato-Sensory Evoked Potential (SSEP) or Evoked Potential Assessment Device (EPAD). During an operation, neuromuscular monitoring can tell doctors if the nerves being studied are working normally or if they are at risk for injury. This study will help investigators to understand what kind of monitoring is best to prevent nerve injuries during a surgical procedure.
详细描述
As standard of care, research participants undergoing a living donor liver transplant or other liver surgeries will receive a right-sided radial arterial line to monitor his/her blood pressure along with the compression of important vessels during surgery. These measurements will be captured throughout the surgical procedure. If blunting of the arterial line wave form occurs, the anesthesiology team alerts the surgical team to release the retractors until the wave form returns to baseline. Depression of the radial arterial line wave form will be captured, time-stamped, and stored by the research transplant anesthesiology team.
Additionally as part of research, participants will receive neuromuscular monitoring using SSEP or EPAD to measure their nerve signals during the surgery (3-6 hours). SSEP or EPAD measurements will occur at the median and ulnar nerve and will be captured throughout the surgical procedure. The research neuromonitoring team will consists of highly skilled technicians, who monitor patients during neurosurgical and orthopedic surgeries. SSEP or EPAD output captured during the surgery will be time-stamped, stored, and interpreted by a Neurologist. To investigate if a correlation exists, SSEP or EPAD abnormalities will be correlated and analyzed with the arterial wave form depressions.
To determine whether a correlation exists with clinical outcomes, a prospective medical record review will be conducted. Before performing the prospective medical record review, authorized research personnel will obtain informed consent from each participant.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 21 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •All adult living liver donors and liver surgery patients at Northwestern Memorial Hospital (surgical setup is similar for living liver donor surgery and liver surgery (e.g. retractors, arterial line for monitoring, surgeons). Investigators will approach both living liver donors and liver surgery patients for enrollment to receive additional neuromuscular monitoring.
- •All subjects must have given signed, informed consent prior to registration on the study.
排除标准
- •Anyone not meeting the inclusion criteria.
结局指标
主要结局
A change in arterial line wave form and a change in the neuromuscular signal using SSEP or EPAD will be measured and tested with the Pearson correlation coefficient as well as nonparametric Spearman's rank correlation coefficient.
时间窗: 12 mos
To establish the correlation between the wave form of the arterial line readings and neuromuscular monitoring.
次要结局
未报告次要终点
研究者
Daniela Ladner
Associate Professor of Surgery
Northwestern University
