A Retrospective Propensity Score Matched Analysis Reveals Superiority of Hypothermic Machine Perfusion Over Static Cold Storage in Deceased Donor Kidney Transplantation.
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 347
- 试验地点
- 1
- 主要终点
- Delayed graft function (DGF)
研究概览
简要总结
Hypothermic machine perfusion (HMP) is considered superior to static cold storage (SCS) in kidney transplantation, but the true benefit in the real-world experience remains incompletely understood.
The aim of our study is to investigate the real-world impact of HMP on kidney graft function after deceased donor kidney transplant in an HMP cohort propensity score matched with SCS.
Propensity score matching will be based on CIT, ECD, gender mismatch, CMV mismatch, re-TX and ET-senior program with a caliper of 0.05
研究设计
- 研究类型
- Observational
- 观察模型
- Case Control
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •single kidney transplantation from a deceased donor at Medical University of Innsbruck between 08/2015 and 12/2019
排除标准
- •combined kidney transplantation with an other organ
- •living donor kidney transplantation
结局指标
主要结局
Delayed graft function (DGF)
时间窗: 7 days post transplant
DGF was defined as the need for at least one dialysis within the first seven days after transplant with the exception of dialysis for hyperkalemia or hypervolemia within the first 12 hours post-transplant
次要结局
- graft survival(24 months post transplant)