Detection of Circulating Plasmablast in Diagnosis and Relapse Prediction of IgG4 Related Diseases
试验速览
- 阶段
- 不适用
- 入组人数
- 660
- 试验地点
- 1
- 主要终点
- plasmablast/plasma cells in the diagnosis of IgG4-RD
研究概览
简要总结
300 IgG4-RD patients, 200 other autoimmune diseases, 60 IgG4-RD mimickers and 100 healthy controls were enrolled. Circulating plasmablast/plasma cells were detected of all patients at baseline and healthy controls. IgG4-RD patients were followed up every 3-6 months. Circulating plasmablast/plasma cells were also detected at disease remission and relapse. IgG4-RD patients' clinical data and laboratory parameters were collected.
详细描述
300 IgG4-RD patients, 200 other autoimmune diseases, 60 IgG4-RD mimickers (pancreatic cancer, cholangiocarcinoma, vasculitis, lymphoproliferative diseases, inflammatory bowel disease, kimura disease) and 100 healthy controls were enrolled. Peripheral blood samples of 5-10 ml were collected from all patients and healthy controls. Serum was separated for ELISA detection. Circulating plasmablast/plasma cells were detected of all patients at baseline and healthy controls. IgG4-RD patients were followed up every 3-6 months. Circulating plasmablast/plasma cells were also detected at disease remission and relapse. IgG4-RD patients' clinical data and laboratory parameters were collected. Data were analyzed to evaluate plasmablast/plasma cells in diagnosis and relapse prediction of IgG4-RD.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •IgG4-RD patients fulfilled the 2011 comprehensive diagnostic criteria of IgG4-RD (2011). Other autoimmune disease and IgG4-RD mimickers fulfilled the corresponding diagnostic criteria.
排除标准
- •Patients in pregnancy or preparing to pregnancy, patients with active infection, including HIV, HCV, HBV, TB, et al.
结局指标
主要结局
plasmablast/plasma cells in the diagnosis of IgG4-RD
时间窗: 24 months
plasmablast/plasma cells will be detected in IgG4-RD, other autoimmune disease and IgG4-RD mimickers at baseline.
plasmablast/plasma cells in relapse prediction of IgG4-RD
时间窗: 24 months
IgG4-RD patients will be followed up for at least 6 months. plasmablast/plasma cells will be detected at baseline, disease remission and disease relapse.
次要结局
未报告次要终点