A Controlled Evaluation of the Spectra Optia® Apheresis System's Granulocyte / Polymorphonuclear (PMN) Cell Collection Procedure

Terumo BCT6 个研究点 分布在 1 个国家目标入组 42 人开始时间: 2013年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
42
试验地点
6
主要终点
Granulocyte/PMN Cell Collection Efficiency

研究概览

简要总结

The purpose of this study is to compare the procedures for the collection PMN cells on Terumo BCT's Spectra Optia® and COBE® Spectra Apheresis Systems.

详细描述

The purpose of this study is to compare the procedures for the collection of granulocyte/ polymorphonuclear (PMN) cells on Terumo BCT's Spectra Optia® and COBE® Spectra Apheresis Systems and to establish the non-inferiority of the Spectra Optia Apheresis System with respect to the primary study endpoint, granulocyte/PMN cell collection efficiency.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Acceptable health status and vital signs per the AABB blood donation guidelines to permit blood donation, including:
  • Blood pressure ≥ 90/50 and ≤ 200/120 mmHg,
  • Pulse > 40 and < 100 beats/min, and
  • Temperature < 99.5ºFahrenheit (F).
  • Able to read, understand, and sign an English informed consent form.
  • Age ≥ 18 years.
  • Weight ≥ 50kg and < 227kg.
  • Male or non-pregnant, non-nursing female (a negative serum pregnancy test at screening and a negative urine pregnancy test prior to each mobilization).
  • Acceptable screening laboratory test results prior to the first PMN cell mobilization, including:
  • WBC count in the range: 3,500-10,800/uL,
  • Hematocrit in the range: 38-65%,
  • Platelet count in the range: 150,000-400,000/uL,
  • Coagulation tests: PT not greater than 1.1 times the upper limit of the local laboratory reference range; PTT not greater than 1.2 times the upper limit of the local laboratory reference range,
  • Serum electrolyte concentrations: potassium in the range 3.6-5.1 mmol/L; calcium in the range 8.5-10.3 mg/dL,
  • Serum creatinine not greater than 1.5mg/dL, and
  • ALT not greater than 1.5 times the upper limit of the local laboratory reference range. *** Up to two (2) of the above screening laboratory test results may fall outside of these ranges, if in the judgment of the principal investigator or designee, they do not constitute a significant risk to the subject. Any excused deviations from the above will be listed and summarized with the final report.***
  • Adequate dual peripheral venous access to allow collection of granulocytes (PMN cells) and return of remaining cells, platelets and plasma.
  • If male, willing to use a condom during sexual relations with a female partner of child bearing potential until 48 hours following each G-CSF injection.
  • If female, willing to use a medically-acceptable contraceptive until 48 hours following each G-CSF injection.

排除标准

  • Positive screening for any of the following: HIV, HBV (except isolated HB core Ab reactivity), HCV, HTLV, Syphilis or West Nile Virus.
  • Currently pregnant or breast-feeding.
  • Collection or loss of specific volumes of whole blood or blood components during specified timeframes:
  • more than 550mL of whole blood within the prior 56 days, or
  • more than 3L of whole blood or 1.5L of red blood cells within the prior 12 months, or
  • more than 12L of plasma within the prior 12 months, or
  • a leukapheresis within the prior six weeks, or
  • a plateletpheresis within the prior 48 hours or two within the prior 7 days or twenty-four within the last 12 months, or
  • a plasmapheresis within the prior 48 hours or two within the prior 7 days.
  • History of congestive heart failure.
  • History of uncontrolled hypertension (SBP/DBP >200/120 mmHg).
  • History or suspicion of active, peptic ulcer disease.
  • History of diabetes mellitus.
  • History of hematologic malignancy or chronic hematologic disorder.
  • Family history (parents, siblings, children) of hematologic malignancy.
  • History of deep vein thrombosis or venous thromboembolism, or bleeding disorder.
  • History of sickle cell disease or a positive SickleDex screen.
  • History of iritis or episcleritis.
  • History of autoimmune condition or disorder, unless approved by principal investigator.
  • Presence of psychological traits, or physiological or medical conditions that, in the opinion of the investigator, would make the subject unlikely to tolerate the procedures or complete the study.
  • History of use/anticipated need for lithium.
  • Received a G-CSF injection in the prior 4 months.
  • Known hypersensitivity to ethylene oxide.
  • Known hypersensitivity to G-CSF or hypersensitivity to any E. coli-derived products.
  • Known hypersensitivity to HES or corn.
  • Concurrent participation in another clinical trial or participation in a clinical trial within the past 30 days.
  • Subject is being treated with calcium channel blockers and/or antiepileptic medications. Note: This applies only to Subjects at Bonfils Blood Center whose collected product will undergo neutrophil function testing.

结局指标

主要结局

Granulocyte/PMN Cell Collection Efficiency

时间窗: within 1 hour prior and within 5 minutes after each collection procedure

The primary endpoint is the granulocyte/PMN cell collection efficiency (CE) associated with the Granulocyte (PMN) Collection Procedures on the Spectra Optia and COBE Spectra Apheresis Systems. CE is a measurement of device performance calculated using donor and blood product blood counts collected immediately before and after the PMN collection procedure.

次要结局

  • Characterization of Blood Product - PMN Cell Yield(within 5 minutes after each collection procedure)
  • Characterization of Blood Product - PMN Cell Yield Per Liter of Blood Processed(within 5 minutes after each collection procedure)
  • Characterization of the Blood Product - PMN Cell Viability(within 5 minutes after collection procedure)
  • Characterization of the Blood Product - Volume(within 5 minutes after collection procedure)
  • Usability/Assessment of System Operation - Device Malfunctions(Result know immediately upon successful completion of procedure)
  • Performance(within 1 hour prior and within 5 minutes after each collection procedure)
  • Characterization of the Blood Product - RBC Contamination(within 5 minutes after collection procedure)
  • Safety(48-hours after last procedure)
  • Usability/Assessment of System Operation - Time(Result captured immediately upon completion of procedure)
  • Usability/Assessment of System Operation - Adjustments(Adjustments known immediately upon completion of the procedure)

研究者

发起方
Terumo BCT
申办方类型
Industry
责任方
Sponsor

研究点 (6)

Loading locations...

相似试验