跳至主要内容
临床试验/NCT06743568
NCT06743568招募中不适用

Efficacy of Self-expandable and Balloon-expandable Valves in Patients With Ascending Aortic Dilation

China National Center for Cardiovascular Diseases3 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2024年10月15日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
100
试验地点
3
主要终点
Device success

研究概览

简要总结

This study evaluated the efficacy of self-expandable valves and balloon-expandable valves in patients with ascending aortic dilation who undergo transcatheter aortic valve replacement.

详细描述

Ascending aortic dilation (AAD) is a common feature in patients with aortic stenosis, especially in those with bicuspid aortic valve. According to the 2022 AHA/ACC Guideline for the Diagnosis and Management of Aortic Disease, in patients undergoing surgical aortic valve replacement who have a concomitant AAD with a maximum diameter of ≥45mm, ascending aortic replacement is reasonable when performed by experienced surgeons in a Multidisciplinary Aortic Team (Class 2a, Level B-NR). However, in patients undergoing transcatheter aortic valve replacement, the impact of ascending aortic dilation remains unclear. Therefore, we designed this multicenter prospective randomized controlled trial, aiming to assess the efficacy of self-expandable and balloon-expandable valves in patients with AAD with a maximum diameter of ≥45mm.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
65 Years 至 —(Older Adult)
性别
All
接受健康志愿者

入选标准

  • Severe AS defined as an aortic valve area (AVA) of 1cm2 or less or an indexed AVA of 0.6 cm2/m2 or less;
  • Evaluation and selection for TAVR by the multidisciplinary heart team;
  • Maximum ascending aortic diameter between 45mm and 54mm on preoperative contrast-enhanced computed tomography (CT) scan
  • Anatomic suitability for a transfemoral vascular access;
  • Life expectancy of more than 12 months;
  • Age ≥65 years.

排除标准

  • Pure aortic regurgitation;
  • History of surgical or transcatheter aortic valve replacement (valve in valve);
  • History of any aortic surgery;
  • Emergent surgery;
  • Patients who refused to be randomized or unable to complete regular follow-up.

结局指标

主要结局

Device success

时间窗: Perioperative period

(1) freedom from mortality; (2) successful access, delivery of the device, and retrieval of the delivery system; (3) correct positioning of a single prosthetic heart valve into the proper anatomical location; (4) freedom from surgery or intervention related to the device or to a major vascular or access-related, or cardiac structural complication; (5) intended performance of the valve (mean gradient \<20mmHg, peak velocity \<3m/s, Doppler velocity index ≥0.25, and less than moderate aortic regurgitation).

30-day all-cause mortality

时间窗: 30 days

30-day all-cause mortality

30-day adverse aortic events

时间窗: 30 days

Aortic-related death, aortic dissection, or aortic rupture.

次要结局

  • 1-year all-cause mortality(1 year)
  • 1-year cardiovascular mortality(1 year)
  • 1-year adverse aortic events(1 year)
  • Aortic expansion rate≥3mm/year(1 year)

研究者

发起方
China National Center for Cardiovascular Diseases
申办方类型
Other Gov
责任方
Sponsor

研究点 (3)

Loading locations...

相似试验