跳至主要内容
临床试验/NCT06166901
NCT06166901已完成不适用

Evaluation of Long-term Safety and Performance of AcrySof PanOptix Trifocal & PanOptix Trifocal Toric Intraocular Lens (IOL)

Alcon Research7 个研究点 分布在 1 个国家目标入组 211 人开始时间: 2024年4月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
211
试验地点
7
主要终点
Mean Binocular Best Corrected Distance Visual Acuity (BCDVA)

研究概览

简要总结

The purpose of this Post-Market Clinical Follow-up (PMCF) study is to describe the long-term safety and performance of the AcrySof IQ PanOptix IOL toric and non-toric models in subjects bilaterally implanted with these IOLs for 3 to 5 years. This study will be conducted in Spain.

详细描述

Subjects will be recruited from a population that has already undergone lens implantation. Retrospective data will be collected from the pre-operative and surgical visits and any safety outcomes reported prior to enrollment. Prospective data will be collected at Visit 1, which will occur Year 3-5 postoperative.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subject or legally authorized representative must be able to understand and sign an Institutional Review Board (IRB)/Independent Ethics Committee (IEC) approved informed consent form.
  • Subject must have had bilateral implantation of AcrySof PanOptix and/or AcrySof PanOptix Toric IOL models for 3 to 5 years prior to enrollment. A subject may have a toric lens in one eye and a non-toric in the fellow eye.
  • Subject must have a documented medical history and required pre-operative baseline information available for retrospective data collection.

排除标准

  • Subject currently participating in another investigational drug or device study.
  • Subject has had corneal refractive surgery after AcrySof PanOptix or AcrySof PanOptix Toric IOL implantation.
  • Subject exposed to a study IOL for a minimum of 3 years prior to Visit 1 that have subsequently undergone an IOL exchange and are no longer implanted with a study IOL at the time of enrollment.
  • Subject is pregnant or nursing at the time of enrollment.

结局指标

主要结局

Mean Binocular Best Corrected Distance Visual Acuity (BCDVA)

时间窗: Year 3-5 postoperative (Visit 1, Day 1)

BCDVA was assessed for both eyes together at a distance of 4 meters using letter charts and recorded in logarithm of the minimum angle of resolution (logMAR). The LogMAR VA scale ranges from -0.30 (20/10 Snellen) to 1.00 (20/200 Snellen). A LogMAR value of 0 equates to 20/20 Snellen VA (normal distance eyesight), with negative LogMAR values representing better than 20/20 VA. Subjects with at least one implanted eye with a toric IOL were categorized as toric as specified in the statistical analysis plan. No hypothesis testing was pre-specified for this endpoint.

Number of Eyes Experiencing an Ocular Adverse Event by Toricity

时间窗: Retrospective data from preoperative visit to Year 3-5 postoperative (Visit 1, Day 1)

Ocular adverse events were identified retrospectively from chart review of operative and immediate postoperative activities and prospectively at Visit 1 (Year 3-5 postoperative). Examples of ocular adverse events include the following: * Cystoid Macular Edema (CME) * Hypopyon * Endophthalmitis * Lens dislocation * Pupillary block * Retinal detachment * Secondary Surgical Interventions (explantation/exchange/repositioning) This outcome measure was pre-specified for eye-based reporting.

Number of Subjects Experiencing a Non-Ocular Adverse Event

时间窗: Retrospective data from preoperative visit to Year 3-5 postoperative (Visit 1, Day 1)

AEs were identified retrospectively from chart review of operative and immediate postoperative activities and prospectively at Visit 1 (Year 3-5 postoperative).

Number of Device Deficiencies by Toricity

时间窗: Retrospective data from preoperative visit to Year 3-5 postoperative (Visit 1, Day 1)

Device deficiencies were identified retrospectively from chart review of operative and immediate postoperative activities and prospectively at Visit 1 (Year 3-5 postoperative). Examples of device deficiencies include the following: * Failure to meet product specifications (e.g., incorrect IOL power) * IOL defect * Broken IOL optic * Broken IOL haptic * Scratched IOL optic * Unsealed device packaging * Suspected product contamination * Lack of performance This outcome measure was pre-specified for eye-based reporting.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (7)

Loading locations...

相似试验

Evaluation of Long-term Safety and Performance of... | 临床试验