Continuous Regional Analysis Device for Neonate Lung

University Hospital Schleswig-Holstein4 个研究点 分布在 3 个国家目标入组 200 人开始时间: 2016年11月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
200
试验地点
4
主要终点
Change in aggregate measure of ventilation homogeneity (coefficient of variation and global inhomogeneity index of regional tidal volume) by > 10% compared with baseline

研究概览

简要总结

The purpose of the study is to assess whether Electrical Impedance Tomography (EIT) has the potential to optimize the ventilator therapy, validate the effectiveness, efficacy and safety of nursing and medical interventions (endotracheal suctioning, posture changes, surfactant therapy, recruitment manoeuvres, etc.) and for early recognition of complications like pneumothorax and endotracheal tube misplacement. The study design is purely observational.

详细描述

EIT data will be recorded during 72 hours of routine clinical treatment. To prevent any decisions based on EIT information, the clinicians will be blinded to the EIT findings during the study period. Data on clinical interventions and clinical findings will be recorded using a specially adapted graphical user interface on the EIT device in combination with a paper-based case report form (CRF). EIT data analysis will be performed off-line.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
— 至 7 Years(Child)
性别
All
接受健康志愿者

入选标准

  • Written, informed consent of both parents or legal representative
  • Admission in the NICU or PICU
  • Patients with or at high risk of developing respiratory failure needing respiratory support.
  • o i.e. (oxygen need (FiO2>25%) AND noninvasive or invasive respiratory support) AND/OR repeated apnea with desaturations
  • Age from birth to 7 years o Initial focus will be on neonates up to 6 kg and 12 months age. Infants of higher weight up to 7 years age will be included as EIT belts for this age group become available.

排除标准

  • Post menstrual age less than 25 weeks
  • Body weight < 600 g
  • Electrically active implants
  • Thorax skin lesions
  • Prior participation for the same diagnosis of lung disease

结局指标

主要结局

Change in aggregate measure of ventilation homogeneity (coefficient of variation and global inhomogeneity index of regional tidal volume) by > 10% compared with baseline

时间窗: 72 hours

Change in right-to-left and/or anteroposterior ventilation distribution by >10% compared with baseline

时间窗: 72 hours

Time and duration of right-to-left or left-to-right ventilation ratio >2:1

时间窗: 72 hours

Percentage of EIT examination time with at least 26 out of 32 sensors exhibiting skin contact impedance of < 700 Ohm

时间窗: 72 hours

Skin contact impedance will be monitored continuously by the EIT device. If more than 6 sensors exhibit skin contact impedance \> 700 Ohm, the examination is no longer suitable for analyzing. To assess the percentage of EIT measurements suitable for analyzing, we will calculate the percentage of EIT examination time with at least 26 out of 32 sensors exhibiting skin contact impedance of less than 700 Ohm.

次要结局

  • Relationship between time of intubation/extubation and EIT findings(72 hours)
  • Relationship between time of onset/end of non-invasive respiratory support and EIT findings(72 hours)
  • Relationship between time of suctioning and EIT findings(72 hours)
  • Relationship between time and type of posture change and EIT findings(72 hours)
  • Relationship between time of surfactant administration and EIT findings(72 hours)
  • Relationship between time of clinically indicated radiological examination and EIT findings(72 hours)
  • Relationship between time of confirmed pneumothorax and EIT findings(72 hours)
  • Relationship between time of confirmed endotracheal tube malposition and EIT findings(72 hours)
  • Relationship between fraction of inspired oxygen over time and EIT findings(72 hours)
  • Relationship between time of recruitment manoeuvre and EIT findings(72 hours)
  • Relationship between primary cause of respiratory failure and EIT findings(72 hours)
  • Relationship between saturation of peripheral oxygen over time and EIT findings(72 hours)

研究者

发起方
University Hospital Schleswig-Holstein
申办方类型
Other
责任方
Principal Investigator
主要研究者

Inez Frerichs

Prof. Dr. Inéz Frerichs

University Hospital Schleswig-Holstein

研究点 (4)

Loading locations...

相似试验

Continuous Regional Analysis Device for Neonate Lung | 临床试验