跳至主要内容
临床试验/NCT06308055
NCT06308055招募中不适用

Abiomed IMPELLA-RT-DAQ - Impella Real Time Data AcQuisition

Abiomed Inc.9 个研究点 分布在 3 个国家目标入组 125 人开始时间: 2024年10月4日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
Abiomed Inc.
入组人数
125
试验地点
9
主要终点
Collection of hemodynamic parameters (Cardiac Output in l/min)

研究概览

简要总结

Abiomed IMPELLA-RT-DAQ - Impella Real Time Data AcQuisition

详细描述

The objective of this study is to develop algorithms for determining the cardiac output through the synchronous acquisition of hemodynamic data from the pulmonary artery catheter or other pressure sensors and Impella using a network module, which can replace invasive hemodynamic monitoring in the future.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Ongoing or planned intensive care management with Impella support
  • Presence or planned placement of a cardiac output measurement
  • Preferentially pulmonary catheter (including cardiac output (CO) preferred as continuous measurement)
  • Other means of discontinuous CO measurement incl. echocardiography, other thermodilution methods

排除标准

  • Age < 18 years
  • Anticipated support duration <24 h

结局指标

主要结局

Collection of hemodynamic parameters (Cardiac Output in l/min)

时间窗: From Impella insertion unitl Impella support is permanently weaned, on average 2 days

Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.

Collection of hemodynamic parameters (Blood Pressure in mmHg, Pulmonary Artery Pressure in mmHg, Central Venous Pressure in mmHg, Pulmonary Capillary Wedge Pressure in mmHg)

时间窗: From Impella insertion unitl Impella support is permanently weaned, on average 2 days

Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.

Collection of hemodynamic parameters (Mixed Venous Saturation in %)

时间窗: From Impella insertion unitl Impella support is permanently weaned, on average 2 days

Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.

Collection of hemodynamic parameters (Pulmonary Vascular Resistance in In dynes/sec/cm-5 )

时间窗: From Impella insertion unitl Impella support is permanently weaned, on average 2 days

Synchronous data acquisition of the Impella system parameters (pressure measurement, motor current, operating data) and the monitoring system (Philipps IntelliVue) using a network module (HighDim) that is connected by either a wired or wireless access.

次要结局

  • Rate of Patient Survival(Once the Impella support is permanently weaned, on average 2 days)

研究者

发起方
Abiomed Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (9)

Loading locations...