NCT03001674已完成不适用
Clinical Hemodynamic Study of Balloon Counterpulsation in Advanced Heart Failure
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 15
- 试验地点
- 2
- 主要终点
- Impact of Intra-aortic Balloon Pump Activation on Left Ventricular Stroke Work.
研究概览
简要总结
The primary objective of this study is to develop normative hemodynamic data (means and standard deviations) for the intra-aortic balloon pump (IABP) using pressure-volume loop and 3D-echocardiographic analyses.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 75 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Male or females between 18-75 years of age
- •NYHA Class III-IV heart failure at the time of MEGA deployment
- •Stage C-D systolic heart failure
- •Non-ischemic cardiomyopathy
- •Preserved right ventricular function defined by 2D-echocardiography
- •Clinically indicated left and right heart catheterization and MEGA-IABP placement
- •Clinically indicated MEGA-IABP support for 12 hours minimum
排除标准
- •Ischemic cardiomyopathy
- •Active myocardial ischemia or acute coronary syndrome
- •Severe peripheral vascular disease
- •Severe aortic or mitral valve insufficiency
- •Severe aortic or mitral valve stenosis
- •Right ventricular failure
- •Inability to tolerate left and right heart catheterization
- •Severe hemodynamic instability defined as a systolic BP <80mmHg despite vasopressor/inotropic support
- •Sustained ventricular tachycardia (>10 beats) within 24 hours and/or ventricular fibrillation within 24 hours
- •Pacemaker dependent rhythm
- •Left ventricular thrombus
- •Rapid atrial fibrillation (HR>120 bpm)
- •Unable to provide informed consent
- •Pregnancy
结局指标
主要结局
Impact of Intra-aortic Balloon Pump Activation on Left Ventricular Stroke Work.
时间窗: 24 hours
We will be measuring left ventricular stroke work using a conductance catheter before and immediately after activation of an intra-aortic balloon pump (IABP). Left ventricular stroke work is quantified as the product of left ventricular pressure and volume. Conductance catheters are the primary method available for clinical measurement of left ventricular volume and pressure.
次要结局
未报告次要终点
研究者
研究点 (2)
Loading locations...
相似试验
Unknown
不适用
Comparison Study of Non-invasive Measurement of Blood Pressure and Cardiac Output During Stress EchocardiographyHigh Cardiac OutputLow Cardiac OutputNCT02422342HeartBeat Technologies LTD50
Unknown
不适用
Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic DeviceIntubation ComplicationHemodynamic InstabilityNCT02918526Azienda Ospedaliero-Universitaria Careggi94
进行中(未招募)
不适用
MicroVention, Inc. Flow Re-Direction Endoluminal Device X (FRED™ X™) Post-Approval StudyIntracranial AneurysmNCT05409989Microvention-Terumo, Inc.154
撤回
不适用
Non-invasive Measurement of Central Hemodynamics by Electrical Impedance TomographyComparison of Availability for Prediction of Volume ResponsivenessComparison of Limits of Agreement for Invasive and Non-invasive Measurement of Stroke Volume VariationNCT01412970Universitätsklinikum Hamburg-Eppendorf
已完成
不适用
Use of Impedance Cardiography and Applanation Tonometry for Prediction of the Antihypertensive Effect of Two DrugsArterial StiffnessAmbulatory Blood Pressure MonitoringNCT03560804AHEPA University Hospital60