Post EVAR Endoleak Detection : Model-based Iterative Reconstruction (MBIR) vs Adaptive Statistical Iterative Reconstruction (ASIR) CTA; a Prospective Study

University Hospital, Clermont-Ferrand2 个研究点 分布在 1 个国家目标入组 90 人开始时间: 2013年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
90
试验地点
2
主要终点
Presence or absence of endoleak after EVAR using CT evaluation

研究概览

简要总结

The purpose of the study is to compare the accuracy of the diagnosis of endoleak in patient with EVAR comparing Adaptive statistical iterative reconstruction (ASIR) CTA and Model-based iterative reconstruction (MBIR- VEO TM).

详细描述

Background:

The aortic aneurysm is a common and serious disease share its complications (rupture ) , often fatal. It is recognized that pass a certain diameter surgical or endovascular treatment reduces mortality by avoiding treatment in extreme provider of high morbidity and mortality emergency. Endovascular anevrysm repair (EVAR) treatment has proven effective but unfortunately this treatment presents complications ( endoleak ) should be sought systematically by repeated checks CT . The irradiation in these patients is a major problem with repeated exposure radiation. The follow up of these patients requires repeated CT because endoleaks can be delayed.

Iterative reconstruction of previous generation have reduced the dose , we dispose the last Model-based iterative reconstruction (" VEO " ) for a further reduction of patient dose . This technique has not yet been evaluated in the detection of endoleaks.

The purpose of the study is to compare conventional CTA (ASIR50) ( gold standard now) with Model-based iterative reconstruction (MBIR- VEO TM) in the detection ( and classification ) of endoleaks in patients traited by EVAR.

All patient admited in Radiology to follow up his EVAR is included in the study and receive both CT: Adaptive statistical iterative reconstruction (ASIR) CTA and Model-based iterative reconstruction (MBIR- VEO TM) and the result of thoses 2 CT are compared by 2 readers (blinded of the result) The BMI , other complications, the DLP , dose reduction and quality of the examination is noted .

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • informed and a written consent
  • all patients consulting to follow up his EVAR
  • 18-90 years

排除标准

  • juvenile patients
  • patient who refusal the study
  • CI of contrast iodine injection : CI of ultravist
  • renal failure creatinemy <30 ml/min

结局指标

主要结局

Presence or absence of endoleak after EVAR using CT evaluation

时间窗: at day 1

次要结局

  • Objective and subjective image quality(at day 1)
  • Diameter of the aneurysm(at day 1)
  • Type of endoleak, BMI (body mass index(at day 1)

研究者

发起方
University Hospital, Clermont-Ferrand
申办方类型
Other