适应症
干预措施

试验速览

阶段
不适用
入组人数
50
主要终点
Matrix Metalloproteinase expression correlate with neointimal plaque volume measure by intravascular ultrasound at 12 months follow up coronary angiography

研究概览

简要总结

If intimal growth is such that the initial lumen is narrowed significantly, distal blood flow is restricted and chronic tissue ischemia results. This occurs in native coronary arteries and during restenosis after coronary angioplasty or failure of some coronary vein grafts. Stent implantation has become the principal revascularization technique for coronary artery disease. But, in-stent restenosis (ISR) by neointimal hyperplasia persists as a significant limitation of this procedure in the era of drug eluting stent (DES). Coronary intervention might induce an inflammatory response by arterial wall damage, release of inflammatory and chemoattractant factors resulting in leukocyte and platelet activation. Then, Migration and proliferation of neointimal smooth muscle cells together with the deposition of extracellular matrix might lead to the development of ISR.

It is known that matrix metalloproteinases (MMPs) play a key role in the pathogenesis of restenosis by controlling extracellular matrix degradation and the release of matrix-degrading MMPs, including MMP -2 and MMP-9, which facilitate intimal remodeling after angioplasty. Previous studies showed that increased levels of MMPs in coronary arteries undergoing percutaneous intervention may be associated with vascular remodeling and restenosis by promoting migration of vascular smooth muscle cells. Recently, Gregory et al. demonstrated that elevated serum activities of MMP-2 and -9 are associated with dramatically increased restenosis rates after PCI with implantation of DES.

In patients with DESs, determination of MMP levels might be useful for identification of patients who are at high risk for ISR. However, not much is known about the relationship between MMPs and neointimal hyperplasia in patients with DES. In this study, the serum activity of MMP-2 and 9 were investigated in patients who had undergone follow-up coronary angiography with intravascular ultrasound (IVUS), which performed at 9 months post-DES implantation. Our aim was to evaluate if individual or combined levels of MMPs were associated with increased neointimal hyperplasia volume, that is, to evaluate the relationship, correlation between the levels of MMPs and neointimal hyperplasia volume.

详细描述

Materials and methods Subjects (patients) Patients derived from a population of patients referred to 12 months follow-up coronary angiography for ischemic heart disease who are enable to be performed IVUS will be enrolled in the present trial, between Dec 2017 and Dec 2018. The study was an all comers design involving consecutive enrollment of patients with stable angina or acute coronary syndrome who had at least 1 coronary lesion (defined as a stenosis of >50%) suitable for stent implantation 9 months before. The follow-up coronary angiography was performed according to standard techniques by experienced interventionalists only. In-stent restenosis was defined as a diameter stenosis ≥50% of the vessel reference diameter by visual assessment at the site of the lesion treated with the stent observed in ≥1 multiple projections. The single most severe view was used to categorize the pattern of restenosis as proposed by Mehran et al for classification of in-stent restenotic lesions. Detailed demographic details including anthropometric measurements, cardiovascular risk factors and medication use were recorded for the participants.

Angiographic analysis (QCA-analysis) The off-line quantitative coronary angiographic analysis was performed with an automated edge-detection system (QCA-CMS Version 6.0, Medis, Medical Imaging Systems, Leiden, the Netherlands). The contrast-filled, non-tapered catheter tip was used for calibration. The reference diameter was measured by interpolation. Minimal lumen diameter (before and after PCI) and diameter stenosis (before and after PCI) were measured within the stent and within the 5-mm proximal and distal edges of the stent. Furthermore, we measured vessel size, lesion length, and length of stented segment. All analyses were performed by the same investigator that was blinded to all laboratory results.

IVUS imaging and analysis IVUS imaging was performed after intracoronary administration of 0.2 mg nitroglycerin, using a motorized transducer pullback (0.5 mm/s) and a commercial scanner (Boston Scientific/SCIMED, Minneapolis, MN) consisting of a rotating 40-MHz transducer within a 3.2 Fr imaging sheath. The decision to perform IVUS was at the operator's discretion. All IVUS data were assessed off-line by experienced professionals unaware of the allocated stent type or clinical information. Using computerized planimetry (EchoPlaque 2.7, Indec Systems, Mountain View, CA), stent and reference segments were assessed every 1 mm. In-stent measurements were obtained every 1 mm and included EEM, stent, intra-stent lumen, peristent plaque+media (EEM minus stent), and IH (stent minus intra-stent lumen) areas and volumes. Percent IH was defined as IH divided by stent. All volumes were calculated using the Simpson rule and then normalized by stent length (normalized volume).

Blood samples Blood samples were taken under fasting conditions directly before follow-up angiography. Arterial blood was drawn from the coronary arteries into serum separator tubes and samples serums were allowed to clot for 30 min before centrifugation at 1,000 g for 10 minutes and stored at -70°C until use.

Laboratory measurement Endogenous MMP-2 and MMP-9 were measured in serum using a standardized enzyme-linked immunosorbent assay (ELISA; R&D systems). This system measures the endogenous activity of the specific MMPs.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Prevention
盲法
None

入排标准

年龄范围
20 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Ischemic heart disease

排除标准

  • Left main coronary artery disease (defined as a stenosis of > 50%)
  • Prior complex lesion morphologies (aorto-ostial, bifurcation with >2.0 mm side branch, severe calcification, chronic total occlusion)
  • Long lesion that require more than two stents
  • Inflammatory conditions likely to be associated with an acute phase response, autoimmune and neoplastic disease
  • Advanced liver disease, renal failure, and valvular heart disease
  • If there was persistent cardiogenic shock, refractory pulmonary edema, or hemodynamic instability (blood pressure <90/50 mmHg).

研究组 & 干预措施

coronary artery disease patients

Experimental

To define the Matrix metalloproteinases expression level in the neointimal hyperplasia induced by DES implantation

干预措施: DES implantation (Device)

结局指标

主要结局

Matrix Metalloproteinase expression correlate with neointimal plaque volume measure by intravascular ultrasound at 12 months follow up coronary angiography

时间窗: One time frame - MMP sampling at 12 month follow up coronary angiography.

Endogenous MMP-2 and MMP-9 were measured in serum using a standardized enzyme-linked immunosorbent assay (ELISA; R\&D systems). This system measures the endogenous activity of the specific MMPs. Neointimal plaque volume measure by intravascular ultrasound at 12 months follow up coronary angiography

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Tae Soo Kang

Associate Professor

Dankook University

相似试验