临床试验/NCT02310776
NCT02310776已完成不适用

Breast Lesion Detection Using the Acuson S2000 Automated Breast Volume Scanner (ABVS) Compared With Handheld (HH) Physician-performed Ultrasound (US) Examinations

Northwestern University4 个研究点 分布在 1 个国家目标入组 501 人开始时间: 2012年6月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
501
试验地点
4
主要终点
Ratio of Lesions Detected With Automated Breast Ultrasound (ABVS) Compared to the Standard of Care Handheld (HH) Breast Ultrasound (US)

研究概览

简要总结

Compare lesion detection of the automated breast ultrasound (ABVS) exam with the conventional handheld (HH) breast ultrasound (US) exam.

详细描述

This is a research study to test a FDA-approved automated breast ultrasound (ABVS) machine in subjects recommended for an ultrasound of the breast. The main purpose of the study is to compare images obtained from the automated breast ultrasound exam with the standard physician performed handheld breast ultrasound exam for lesion detection equivalence.

Each subject will have a bilateral hand-held breast ultrasound and a bilateral automated breast ultrasound, both exams preferably done on the same day. The hand-held ultrasound will be performed by a breast imaging physician participating in the study and the automated ultrasound exam will be performed by a sonographer.

There is no radiation risk from ultrasound. The physician performing the handheld breast ultrasound is blinded to the study, will not know the subject's history, but only the reason for the breast ultrasound exam.

The automated scan requires gentle pressure on the breast during a scan. Three basic views will be acquired for each breast, each scan lasting approximately one minute. Once all necessary views are acquired, the images will be sent to a remote workstation, where a second radiologist, also blinded to the results of the handheld study, will interpret the automated ultrasound.

Once all images and patient information are gathered, the study radiologists will review the previous images, if available, to provide the final result that will determine clinical management. Therefore, it is possible that the hand-held or automated ultrasound scan will lead to further evaluation of the breast and possibly a biopsy.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • anyone who is referred for an ultrasound of the breast

排除标准

  • Subjects whose breast thickness is greater than 6 cm.The maximum depth of image filed for the ABVS acquisition is 6 cm

结局指标

主要结局

Ratio of Lesions Detected With Automated Breast Ultrasound (ABVS) Compared to the Standard of Care Handheld (HH) Breast Ultrasound (US)

时间窗: Time for performance of ABVS was measured separately from interpretation time. Time for performance of real time HH whole breast US was also measured. For HH US physician performed, performance included interpretation.

Solid lesions found on whole breast 3D supine automated breast ultrasound are compared in number and identity with solid lesions found using high resolution standard of care handheld breast ultrasound performed by physicians

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ellen Mendelson

MD, FACR, Lee F. Rogers Professor of Medical Education in Radiology, Professor of Radiology Feinberg School of Medicine