跳至主要内容
临床试验/NCT04047927
NCT04047927Unknown不适用

A Single Arm, Open-label First In Human Study for Assessing the Safety and Performance of the EpiFinder in Subjects With Clinical Indication for Lumbar Epidural Steroids Injection (ESI)

Omeq Medical2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2019年12月15日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
15
试验地点
2
主要终点
Safety - Device Related Serious Adverse Events

研究概览

简要总结

The EpiFinder device, which is the investigational device in this study, is intended for use in epidural procedures, between a luer syringe and an epidural needle, to give the treating physician a clear indication that the needle tip has entered the epidural space. The objective of this First In Human study is to evaluate the safety and performance of using the EpiFinder to identify the epidural space in subjects with a clinical indication to receive a lumbar Epidural Steroid Injections.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Subject is 18 years or older
  • Subject with clinical indication for lumbar ESI based on subject's clinical problem (e.g. DDD hernia disc, spinal stenosis)
  • Subject understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed

排除标准

  • Subject with marked spinal deformities
  • Previous back surgery
  • Contraindication for epidural injections (e.g. continuous use of anticoagulants, infection, allergic reactions to the injected substances)
  • Subject has known hypersensitivity to contrast media that cannot be pre-medicated
  • Subject with severe obesity (body mass index >35 kg/m2)
  • Subject observed seizure within 7 days prior to study enrollment
  • Subject presenting for emergency
  • Subject has a skin condition (i.e., hemangioma, scleroderma, psoriasis, rash, open wound or tattoo) in their lumbar region
  • Subject is pregnant (to be determined by urine pregnancy test)
  • Subject who is currently participating or has participated in an investigational study, within the past 30 days

结局指标

主要结局

Safety - Device Related Serious Adverse Events

时间窗: 14 days

cumulative incidence of device-related complications and Serious adverse events (AE), observed during the procedure and throughout the follow-up period. Device related adverse events include: dural puncture with or without headache, epidural hematoma, seizures, neurological deficit or relevant device complications. All related and non-related adverse events will be observed on a continuous basis from the baseline through the study completion.

次要结局

  • Device Performance - Physician satisfaction(Procedure)
  • Device Efficacy - Epidural Space Identification(Procedure)

研究者

发起方
Omeq Medical
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验