The Long-term Effects of an Implantable Drop Foot Stimulator on Gait in Hemiparetic Patients

Medical University of Vienna0 个研究点目标入组 10 人开始时间: 2012年7月26日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
10
主要终点
kinematic gait parameters

研究概览

简要总结

The aim of this study is to investigate the effects of the implantable drop foot stimulator "ActiGait" (Ottobock Health Care, Duderstadt, Germany) on gait in hemiparetic patients. While several studies investigated the effects of implanted systems on walking speed and gait endurance, only a few studies have focused on the system's impact on kinematics and long-term outcomes. Therefore, our aim was to further investigate the effects of the implanted system ActiGait on gait kinematics and spatiotemporal parameters with a 1-year follow-up period.

详细描述

Patients with a neurologic condition leading to drop foot during swing phase in gait are treated by the implentation of the AcitGait system (which has a CE-certificate in Europe).

The aim of this study is to investigate the effect of the device on gait with a follow-up period of one year. Patients are assessed before implantation and at one-year follow up. At baseline, they are asked to walk without any assistive device, as well as with surface electrical stimulation of the peroneal nerve. At follow-up, they are asked to walk with the ActiGait system switched off and switched on.

Outcome assessments include a 10m-walking test and gait analysis with a VICON 3D-camera system. This allows to extract spatio-temporal parameters (as steps per minute, step length,...) as well as kinematic data (e.g. joint ankles during the gait cycle). All outcome data is analyzed using statistical tests.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • drop foot after stroke, brain haemorrhage or multiple sclerosis
  • a minimum of six months after the acute infarction/onset of the disease
  • passive extension of the ankle to at least at neutral position
  • no sufficient active ankle extension
  • free walking without any aid for at least 20 meters in less than 2 minutes
  • a walking speed of ≤ 1,2m/sec (measured with 10 meter walking test)
  • use of surface electrical stimulation for at least three months
  • be able to stand freely

排除标准

  • damage to the peripheral nervous system
  • adiposity
  • substance abuse
  • no cognitive ability to follow the study instructions
  • pregnancy
  • use of other implanted devices
  • instable ankle joint or fixed contracture

研究组 & 干预措施

ActiGait

Experimental

Patients who get the ActiGait implant

干预措施: ActiGait (Device)

结局指标

主要结局

kinematic gait parameters

时间窗: 1 year

Kinematic gait parameters are recorded and analysed using a 3D VICON infra-red camera system.

次要结局

  • spatio-temporal parameters(1 year)
  • Visual Analogue Scale for Health(1 year)
  • 10-m-walking test(1 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Agnes Sturma

Physitherapist, Researcher

Medical University of Vienna