跳至主要内容
临床试验/NCT06844123
NCT06844123招募中不适用

Graft Robot-Assisted Corneal Enhancement

CHU de Reims1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2025年6月6日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
发起方
CHU de Reims
入组人数
10
试验地点
1
主要终点
Descriptive analysis of unusual events intra- and postoperatively

研究概览

简要总结

Full-thickness corneal grafting (transfixing keratoplasty) is a tissue graft described at the beginning of the 20th century, which has remained technically unchanged for several decades. Around 900 transfixing keratoplasties are performed every year in France. This microsurgical procedure is intended for patients with severe corneal pathology that seriously impairs visual function, and for whom no therapeutic alternative - optical devices, medication or other surgical procedure - exists.

The initial anatomical outcome of surgery depends on the accurate execution of the corneal sutures. Very recently, a robot with microsurgical capabilities was developed by the MMI company (Symani® surgical system, now available from the Reims University Hospital). This robot is equipped with forceps and a needle holder capable of handling fragile tissues and microsurgical needles with an amplitude of movement greater than that of the human hand. It is operated by a surgeon via a wireless controller and foot pedal. It could thus be used to perform the usual sutures of a transfixing keratoplasty.

To our knowledge, no study to date has evaluated the contribution of a microsurgical robot to transfixing keratoplasty in humans. The Symani® microsurgical robot recently received CE marking for microsurgery. The investigators were able to carry out a series of ex vivo keratoplasties using the robot to suture non-conforming human corneas (destined for destruction), thus proving the feasibility of the procedure.

On the basis of this proof of concept, our project aims to evaluate the performance of robot-assisted transfixing keratoplasty in patients requiring corneal transplantation. Robotic assistance for human eye surgery, particularly corneal transplants, has never been evaluated. The use of a robot to perform corneal sutures during transfixing keratoplasty could equal or even surpass the performance of this crucial surgical step, which is conventionally performed manually. Ultimately, visual results could be equivalent or even better than those obtained after conventional surgery. At the same time, the use of the robot will be evaluated in terms of surgical cost, in order to obtain a quantified financial evaluation of robot-assisted keratoplasty.

详细描述

Context Transfixing keratoplasty was developed in the early 20th century. The aim is to replace the entire central cornea with a corneal allograft. This microsurgical procedure is performed with the aid of an operating microscope, and under general anesthetic to ensure optimal control of the absence of movement and arteriovenous pressure throughout the procedure.

Suturing is therefore an essential part of transfixing keratoplasty. They determine the congruence of the tissue edges and the distribution of tension applied to the sutures, thus modulating the curvature (astigmatism) of the graft. This curvature will determine the optical properties of the eye, and hence its acuity and the patient's visual recovery. A topical immunomodulatory local treatment (corticosteroids and/or ciclosporin eye drops) is administered for several years; no systemic treatment is used. Sutures are usually removed 6 months to 1 year after surgery. Current indications are major declines in visual acuity - generally below 4/10 with the best possible correction - associated with i) severe keratoconus, the most frequent indication, ii) failed anterior grafts, iii) full-thickness central corneal scars, and iv) hereditary stromal dystrophies.

Robot-assisted surgery has developed considerably over the last twenty years, with procedures now routinely performed in macro- and endoscopic surgery (mainly urology, obstetrics and visceral surgery). Very recently, engineering advances in precision motion control and mechanical miniaturization have enabled the development of robots dedicated to microsurgery. The Symani® Surgical System (Medical MicroInstrument, Pisa, Italy) has been used and evaluated in animals and humans over the past two years for vessel and nerve microsurgery. The Symani® robot is equipped with forceps and a needle holder capable of handling fragile tissue, as well as microsurgical needles and wires (8/0 to 12/0). The Symani® robot has recently been CE-marked for microsurgery [appendix 1]. To date, there is only one study - ex vivo and in animals - on the feasibility of its use in ocular surgery. On the basis of the robot's capabilities and its CE mark, the investigators have carried out preliminary experiments, enabling us to envisage robot-assisted keratoplasty in humans.

On the basis of our preliminary results, the investigators hypothesize that it is possible to use the Symani® robot's assistance to perform the major surgical stage of transfixing keratoplasty, i.e. the sutures between the graft and the recipient cornea, in humans.

Objectives :

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients of legal age seen in a specialized ophthalmology consultation at the Reims University Hospital, and requiring transfixing keratoplasty.
  • •Affiliated to a social security scheme
  • •Agreeing to take part in the study (information and signature of consent form).

排除标准

  • •Patients protected by law
  • •Patients with an ocular pathology other than their corneal pathology.
  • •Mentally incapable of adhering to the principles of the study.

研究组 & 干预措施

Robot-assisted keratoplasty group

Experimental

patients undergoing robot-assisted corneal transplantation

干预措施: Robot-assisted keratoplasty (Procedure)

结局指标

主要结局

Descriptive analysis of unusual events intra- and postoperatively

时间窗: Day O (intraoperative) to Day 7

Number and percentage of unusual events

Descriptive analysis of unusual events

时间窗: Day 7 to Day 90

Number and percentage of unusual events

次要结局

  • Visual acuity with correction(Day 90)
  • Corneal topographic regularity(Day 90)
  • Subjective refraction(Day 90)
  • Postoperative corneal anatomical result(Day 90)
  • Visual acuity without correction(Day 90)
  • Analysis of surgical costs(Month 6)
  • National Eye Institute Visual Function Questionnaire(Day 90)

研究者

发起方
CHU de Reims
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

Microsurgical Robot-assisted Corneal Transplant | 临床试验