跳至主要内容
临床试验/NCT05804435
NCT05804435撤回不适用

Prospective Multi-center Study Using a Bronchoscopic Ultrasound-Guided Needle Biopsy System With Real-time Visualization in Endobronchial Lesions, Peripheral Lung Nodules, or Lung Masses

Boston Scientific Corporation0 个研究点开始时间: 2025年1月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
主要终点
Proportion of patients where the needle is visualized by the iNOD system inside the lesion

研究概览

简要总结

The purpose of this study is to collect information on the iNod™ System's safety and ability to see the iNod™ biopsy needle in real-time in endobronchial lesions, peripheral lung nodules, or lung masses.

详细描述

This post-market study intends to further demonstrate the ability and safety of the iNod™ Ultrasound Guidance System and iNod™ Ultrasound Biopsy needle to perform transbronchial needle biopsy of endobronchial lesions, peripheral lung nodules, or lung masses under real-time ultrasound visualization. This is a prospective, multi-center case series of standard of care peripheral lung nodule biopsy procedures with up to 115 subjects at up to 10 centers.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18 years or older.
  • Subject willing and able to comply with study procedures and provide written informed consent to participate in study.
  • Subject with a predominantly solid, peripheral lung lesion, 1 cm to 5 cm in diameter measured along its longest cross sectional diameter on axial CT imaging (obtained within 4 weeks per standard of practice) with the intention to undergo a clinically indicated bronchoscopic evaluation under routine clinical care. If the lesion is partially solid (i.e. there is a ground glass component) then the solid portion must make up at least 80% of the lesion.
  • a. "Peripheral" lesion in this study will be pragmatically defined as any lesion in the lung parenchyma that the clinician feels cannot be accessed successfully using the convex probe endobronchial ultrasound bronchoscope.
  • Subject for whom the decision to pursue biopsy has been made by the treating physician and agreed upon by the subject.

排除标准

  • Subjects with pure ground glass opacity or a subsolid target lesion, and/or a ground glass opacity for which less than 80% of the lesion is solid identified by Chest CT.
  • Subjects who have medical contraindication to undergo conventional flexible or robotic bronchoscopy and standard of care Radial EBUS-guided cytological assessment evaluations, as determined by the investigator.
  • Subjects with known coagulopathy.
  • Subjects who are pregnant or nursing mothers.
  • Subjects who are currently enrolled in another investigational study that would directly interfere with the current study, without prior written approval from the sponsor.
  • Use of intraprocedural Cone Beam CT, Fixed CT or Augmented fluoroscopy

结局指标

主要结局

Proportion of patients where the needle is visualized by the iNOD system inside the lesion

时间窗: Procedure

Successful "Tool in lesion", defined as visualization of the tracheobronchial biopsy needle (TBNA) inside the targeted lesion within the ultrasound field of view.

Adverse Events

时间窗: Procedure

Proportion of subjects with Adverse Events related to the iNod device and/or study procedure, as well as Adverse Events related to any subsequent crossover procedures.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

相似试验