Automated Respiration Rate Evaluation to Improve Accuracy of the Early Warning Score Procedure Determined by the Electronic Cardiac Arrest Risk Triage Score (eCART) Algorithm
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 133
- 试验地点
- 1
- 主要终点
- Time of Detection
研究概览
简要总结
Currently, breathing rate and heart rate are checked by nursing staff manually every few hours and entered into a patient's medical record. The investigators are doing this study to see if a device that will automatically record breathing rate and heart rate every 15 minutes is as accurate as the manual measurement. The investigators will also see if these measurements, taken every 15 minutes, will help us predict adverse events more quickly and accurately than the measurements taken every few hours.
详细描述
Both cardiac arrest and sepsis are primarily identified by vital sign abnormalities. However, the practice of nurses and their designees routinely checking hospitalized patients' vital signs every four to eight hours throughout the day and night has remained essentially unchanged for over one hundred years. While respiratory rate has been shown to be the most predictive vital sign for adverse events on the wards, it is often inaccurately measured and poorly documented. For example, a disproportionate amount of respiratory rates are recorded as either 18 or 20 breaths/min, which is often higher than actual rates.
We have previously statistically derived a physiology-based early warning score, called the electronic cardiac arrest risk triage score (eCART), using vital signs and lab values. The eCART was more accurate than scores commonly used in hospitals today. However, the vital sign values utilized for our score were manually collected by nursing staff every four hours. Recent technological advances have allowed for high-frequency measurement of pulse and respiratory rate using a cableless respiration monitor. These devices allow for more frequent and potentially more accurate measures of respiration, which may enhance the prediction ability for detecting adverse events on the wards. In addition, the increase in monitoring frequency may result in earlier detection of adverse events, which could translate into further improvements in patient outcomes.
A subset of patients may be continuously measured using a telemetry system. The alarms and ECGs from these patients are monitored by staff in a centralized station in the hospital. When a clinical event requiring action is observed, a call is made to the unit alerting the clinical staff that action is necessary. We will collect the continuous measurements collected from this system and compare these continuous measurements to the high frequency and manual measurements.
研究设计
- 研究类型
- Observational
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •over 18 years
- •able to provide written consent
排除标准
- 未提供
结局指标
主要结局
Time of Detection
时间窗: 6 months
To determine whether high-frequency (Q15 min) monitoring of pulse and respiratory rates provides earlier detection of patient deterioration than standard validated (Q4hr) vitals or continuous respiratory monitoring (Qcont).
Physiological Validity
时间窗: 6 months
To determine whether high-frequency (Q15min) monitoring provides respiratory rates with greater physiological validity than standard manual (Q4hr) vitals.
Accuracy
时间窗: 6 months
To determine whether high-frequency (Q15min) monitoring provides data with greater accuracy for predicting risk of adverse events than intermittent (Q4hr) validated vitals.
次要结局
- Physiological Validity(6 months)
- Detection Performance(6 months)