The Effect of Fluorescent Marking and BCA Methods of Patient Unit Cleaning in Intensive Care
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 40
- 试验地点
- 1
- 主要终点
- To evaluate the effectiveness of cleaning
研究概览
简要总结
Effective cleaning of surfaces in the hospital environment is an absolute necessity to reduce pathogen transmission. Multi Drug Resistant Organisms (MDRO) in ICU are among the leading causes of hospital-acquired infections. Today, the growing prevalence of MDRO has made it more important than ever to clean contaminated surfaces with appropriate aseptic cleaning procedures, to protect patients and personnel. Despite the disinfection and sterilization methods, microorganisms that reach a sufficient concentration in the hospital environment survive for long periods and can cause serious transmission via contaminated hands of healthcare workers. In this context, surface cleaning and disinfection procedures in the hospital environment reduce cross-contamination of the health care units and disease-causing pathogens. Recently, environmental cleaning and disinfection have become important as well as the evaluation of cleanliness.
The aim of this study is to evaluate the effectiveness and usability of BCA method, which is a new approach in evaluating the effectiveness of environmental cleanliness in intensive care units. fluoroscan gel marking, microbiological sampling and BCA assay methods will be compared to evaluate the effectiveness and usability of the BCA method. (PRO1 Micro Hygiene Monitoring System that System consisting of protein pen and device that analyzes with BCA method).
详细描述
Patients admitted to the ICU are at great risk of developing nosocomial infections, partly because of their serious illness and partly because of exposure to life-saving invasive procedures. In ICU, implementation of invasive procedures, with the purpose of diagnosis and treatment, such as urinary catheter, central-peripheral catheter, intubation, and being subject to intensive antibiotic use increase the likelihood of infection. Environmental cleanliness is important for preventing infections.
Effective cleaning of surfaces in the hospital environment is an absolute necessity to reduce pathogen transmission. Multi Drug Resistant Organisms (MDRO) in ICU are among the leading causes of hospital-acquired infections. Today, the growing prevalence of MDRO has made it more important than ever to clean contaminated surfaces with appropriate aseptic cleaning procedures, to protect patients and personnel. Despite the disinfection and sterilization methods, microorganisms that reach a sufficient concentration in the hospital environment survive for long periods and can cause serious transmission via contaminated hands of healthcare workers. In this context, surface cleaning and disinfection procedures in the hospital environment reduce cross-contamination of the health care units and disease-causing pathogens. Recently, environmental cleaning and disinfection have become important as well as the evaluation of cleanliness.
Cleaning of frequently contacted environmental surfaces, monitoring and verifying the cleaning results are important for patient safety. The effectiveness of environmental cleaning can be assay by different methods. Visual evaluation, ATP (AdenosineTriphosphate) measurement, protein tests and fluoroscan marking methods are some of them.
Evaluation of the patient unit cleanup in the ICU, that is carried out after the discharge of patients with infection or colonization that would require strict contact isolation, by Fluoroscan Marking, BCA and Microbiological Sampling methods, is planned with the aim of collecting data in order to prove the efficiency and clinical employability of the new cleaning assessment method, PRO1 Micro Hygiene Monitoring System (System consisting of protein pen and device that analyzes with BCA method).
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •A patient infected with resistant microorganism in the unit is in the same unit for at least 72 hours
- •The first BCA measurement when the unit is discharged gives a result indicating the unit is dirty.-
排除标准
- •The patient who has been infected with the resistant microorganism in the unit has been hospitalized for less than 72 hours
- •The first BCA measurement when the unit is empty does not give a result indicating that the unit is dirty.
- •Impaired blindness for any reason included in the study
- •In case the patient is included in the study but new patient admission to the unit before the cleaning stages are completed
- •In the event that other employees who are included in the work but do not complete the cleaning stages enter and leave the unit, the work will be terminated.
结局指标
主要结局
To evaluate the effectiveness of cleaning
时间窗: 1 year
The absence of gel residue on the surfaces indicates that the wiping process is effective. Microbiological samples will determine the presence and amount of bacteria (colony) in the environment. It is aimed that bacteria cannot be produced in the samples taken from the environment after cleaning. The BCA protein samples will be analyzed by the researcher using the PRO 1 Micro hygiene monitoring device. PRO 1 Micro hygiene monitoring device will detect the presence of biological material on the surfaces. The presence and amount of bacteria on the surface will be determined with BCA protein. The presence and amount of bacteria can be detected by BCA protein swab, but not by bacterial species. The device is capable of detecting the biological load between 1 - 10 micrograms. Areas with values above 5 micrograms will be considered as dirty, areas with values below 5 micrograms will be considered as clean
次要结局
- To evaluate the effectiveness of BCA method(1 year)
研究者
Zuhal Gülsoy
Lead researcher
Cumhuriyet University