A Randomized Controlled Trial of the Uresta Continence Pessary; Short-term Uresta Efficacy Study (SURE Study)
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 36
- 试验地点
- 2
- 主要终点
- A 50% Reduction in Pad Test Weight
研究概览
简要总结
Stress urinary incontinence (SUI) is defined as the involuntary loss of urine with an increase in abdominal pressure, caused either by a loss of support under the bladder neck, or intrinsic urethral sphincter deficiency. It is a common problem in women that can significantly impact quality of life, with up to 30% developing SUI at some point in their lifetime.
The most commonly utilized treatments for SUI include either pelvic floor (Kegel) exercises, or surgery. Many women find Kegel exercises unsatisfactory, but are reluctant to undergo a surgical procedure. Also, women who are poor candidates for surgery have limited options if Kegel exercises are unsuccessful. Over the years, there have been numerous attempts to develop effective non-surgical alternatives for treating SUI, but the results have been variable and the available data on efficacy limited.
A new intravaginal incontinence pessary (Uresta) has been developed for treating stress incontinence, and is currently available in Canada via a medical distributor. The self-positioning device is initially fitted by a healthcare provider, but then can subsequently placed by the patient as needed. Uresta is designed to be easily inserted into the vagina and spontaneously fall into position, providing support beneath the urethra. A single, uncontrolled study of 21 women showed that Uresta significantly reduces urinary incontinence measures, with no reported complications. Using questionnaires, a 47% reduction in self-reported SUI symptoms was demonstrated. Pad weight following a pad test, an objective assessment of urine loss, showed a 50% reduction in leakage.
This trial is intended to be a short-term assessment of the efficacy of the Uresta device, using a placebo arm in order to remove any of the possible sources of patient biases. The placebo ("sham") group will be obtained by placing a flexible silastic ring (inactivated Estring) high in the vagina where it will not alter urethral forces. The aim is to unequivocally determine whether the Uresta device provides the necessary urethral support to stop urine leakage from stress incontinence.
The hypothesis is that the Uresta device will significantly reduce urinary losses from baseline, shown as a significant reduction pad weight following a pad test with the device in place.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Urodynamic diagnosis of stress urinary incontinence
排除标准
- •Urodynamic diagnosis of mixed incontinence
- •Bladder capacity less than 300mls
- •Post-void residual over 100mls
- •Pelvic organ prolapse greater than POP-Q stage 2
- •Hematuria
- •Undiagnosed vaginal bleeding
- •Current pregnancy
- •Previous incontinence or prolapse surgery
- •Failed use of an incontinence pessary
- •Physically unable to perform the activities included in the pad test
结局指标
主要结局
A 50% Reduction in Pad Test Weight
时间窗: Immediately after device placement (short term).
A pad test is an objective measure of urine loss. With a full bladder, while wearing a pad, the participant completes five repetitions of the following physical activities: coughing, step climbing, heel bounce, standing from a sitting position and walking 50 yards. The weight of the pad is then determined. The primary outcome variable will be the achievement of a 50% reduction in the pad weight before and after device placement. This figure is obtained from the study by Farrell et al, where pad weight decreased from 20 grams to 9 grams with the use of the Uresta device.
次要结局
未报告次要终点
研究者
Danny Lovatsis
Dr.
Mount Sinai Hospital, Canada