跳至主要内容
临床试验/NCT04721392
NCT04721392已完成不适用

Mental Fatigue and Industrial Work Performance: The Influence of the Laevo Exoskeleton

Vrije Universiteit Brussel2 个研究点 分布在 1 个国家目标入组 12 人开始时间: 2021年3月8日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
12
试验地点
2
主要终点
Work performance: Percent accuracy Serial Seven Task

研究概览

简要总结

To investigate the effect of mental fatigue on industrial work performance, biomechanical determinants, (electro-)(psycho-) physiological measures and physical ergonomics. Additionally, the current project wants to evaluate whether or not the Laevo exoskeleton influences the aforementioned parameters when mental fatigue is acutely induced.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 64 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Males and Females
  • 18-64 years

排除标准

  • Musculoskeletal disorders
  • Neurological disorders
  • Cardiovascular disorders
  • Pregnancy

结局指标

主要结局

Work performance: Percent accuracy Serial Seven Task

时间窗: 30 minutes

An audio record of this task will be made to verify made errors posthoc. During the serial seven task participants are given a number between 900 and 950. The given starting number will change each trial. Participants are asked to subsequently subtract seven as fast as possible.The researcher will take note of every answer. If the participant makes an error, he/she may continue to calculate with the wrong number. The ratio of correct answers to the total number of responses will indicate the percent accuracy for each participant.

Ergonomics: EMG-data

时间窗: 30 minutes

Muscle activity during the performance of the industrial task of the erector spinae muscle, m. rectus abdominus, both m. obliqui abdominus, all three parts of m. trapezius, all three of m. deltoideus, m. pectoralis major, m. latissimus dorsi, m. biceps brachii, m. triceps brachii,m. flexor- and extensor carpi radials, m. flexor- and extensor carpi ulnaris, m. flexor- and extensor digitorum, m. gluteus maximus and medius, m. rectus femoris, m. biceps femoris. ; measured with Cometa mini wave.

VICON: Placement accuracy Box

时间窗: 30 minutes

Accuracy of placement box during the dual-task will be measured with VICON. VICON-markers will be placed on the box to track its movement during the trial. First, the optimal position of the box for each level (ground or shoulder) will be determined, these will form the reference frames. Next, the accuracy of each relocation will be determined by the offset compared to these reference frames. This will be calculated into a percentage.

Ergonomics: Joint angles

时间窗: 30 minutes

Joint angles will be measured during the performance of the industrial task to evaluate movement variability. 30 VICON markers will be placed bilateral on the body of the participant on anatomical landmarks.

Mental fatigue: EEG-data

时间窗: 60 minutes

Alpha, Beta and Theta activity in the electroencephalogram measured with open bci (OpenBci, inc)

Mental fatigue: VAS-score

时间窗: 60 minutes

Participants are asked to indicate their subjective feeling on a straight line ranging from "not at all mentally fatigued" to "extreme mentally fatigued"

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Romain Meeusen

Prof. Dr.

Vrije Universiteit Brussel

研究点 (2)

Loading locations...

相似试验