临床试验/NCT03087604
NCT03087604已完成4 期

Loss of Resistance With Nerve Stimulation Versus Loss of Resistance Alone; Effect on Success of Thoracic Epidural Placement.

Wake Forest University Health Sciences1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2017年3月17日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
4 期
状态
已完成
入组人数
100
试验地点
1
主要终点
Success Rate of Placement of a Thoracic Epidural

研究概览

简要总结

The purpose of this randomized, observer-blinded, investigative trial is to determine if the use of electrical stimulation, compared to the traditional loss of resistance technique alone, improves the success rate of epidural catheter placement at an academic teaching institution.

详细描述

All subjects will receive a thoracic epidural catheter placement at the level appropriate for their surgery and will be randomized to either have the epidural placed with a loss of resistance technique alone or loss of resistance technique with confirmation by nerve stimulation. In the traditional loss of resistance technique group, the epidural catheter will be placed after achieving loss of resistance to air. In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall. Nerve stimulation will be started at a pulse width of 0.3 ms and a frequency of 1 Hz and a current of 0.2mA.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Double (Participant, Outcomes Assessor)

盲法说明

As the patient will be sedated during epidural catheter placement, they will be blinded to their treatment arm. The investigator that determines if the epidural was successful placed will also be blinded to the patient's treatment arm.

入排标准

年龄范围
18 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults undergoing intra-thoracic or intra-abdominal procedures that normally would receive thoracic epidurals for post-operative analgesia will be eligible.

排除标准

  • Subjects with contraindications to regional anesthesia:
  • history of allergy to amide local anesthetics
  • presence of a progressive neurological deficit
  • patients that are on anticoagulant medications that prohibit placement of an epidural
  • Systemic infection
  • Infection at the site of placement

研究组 & 干预措施

Traditional Technique Group

Active Comparator

In the traditional loss of resistance technique group, the epidural catheter will be placed after achieving loss of resistance to air. After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.

干预措施: Thoracic epidural block (Procedure)

Traditional Technique Group

Active Comparator

In the traditional loss of resistance technique group, the epidural catheter will be placed after achieving loss of resistance to air. After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.

干预措施: Solution For Thoracic epidural block (Drug)

Electric Stimulation Group

Experimental

In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall. After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.Thoracic epidural block with Electrical Nerve stimulation

干预措施: Thoracic epidural block (Procedure)

Electric Stimulation Group

Experimental

In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall. After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.Thoracic epidural block with Electrical Nerve stimulation

干预措施: Electrical Nerve stimulation (Procedure)

Electric Stimulation Group

Experimental

In the electrical stimulation group, following the location of the epidural space with a loss of resistance technique (using air), nerve stimulation will be utilized to elicit a myotomal contraction of the abdominal or thoracic wall. After placement of the catheter a standard test dose of 3+2 ml of 1.5% lidocaine with 1:200,000 epinephrine will be administered.Solution for Thoracic epidural block.Thoracic epidural block with Electrical Nerve stimulation

干预措施: Solution For Thoracic epidural block (Drug)

结局指标

主要结局

Success Rate of Placement of a Thoracic Epidural

时间窗: 15 minutes after administration of a test dose of lidocaine

will be determined by the detection of a loss of sensation to cold (ice) in at least two contiguous dermatomal levels, 15 minutes after administration of a test dose of lidocaine through the epidural catheter. If a loss of cold sensation is found, then the epidural placement will be classified as successful. If no loss of cold sensation is found, then the epidural placement will be classified as unsuccessful.

次要结局

  • Time Required to Place the Epidural Catheter(From the initiation of procedure to end of procedure)
  • Number of Thoracic Spine Levels Attempted(Thirty minutes after start of procedure.)