跳至主要内容
临床试验/NCT06592001
NCT06592001进行中(未招募)不适用

Assessment of a Chronically Implanted Parasternally Delivered EV-ICD Lead (ASCEND EV) Study

AtaCor Medical, Inc.4 个研究点 分布在 3 个国家目标入组 19 人开始时间: 2025年2月25日最近更新:
适应症

试验速览

阶段
不适用
状态
进行中(未招募)
入组人数
19
试验地点
4
主要终点
Freedom from major ADEs

研究概览

简要总结

The ASCEND EV Study is a prospective, multi-center, single-arm, non-randomized study without concurrent or historical controls. The purpose of the study is to evaluate the Investigational Devices through at least 3-months of follow-up to inform the design of a subsequent pivotal clinical investigation.

The objectives of the study are to: 1) preliminarily validate safety and effectiveness of the Atala™ lead as a permanent ICD lead when used with a compatible ICD pulse generator, 2) evaluate suitability of clinical study testing methods and 3) inform statistically powered primary safety and effectiveness endpoints in a subsequent pivotal clinical investigation.

详细描述

The primary safety endpoint is freedom from major Adverse Device Effects (ADEs) through 3-months. The primary performance endpoint is successful induced ventricular arrhythmia (IVA) test in the final system configuration.

Up to three (3) Investigational Sites will participate with up to 35 Subjects enrolled in the study. Subjects who meet current indications for ICD therapy will be eligible for participation. Eligible Subjects will receive an Atala™ lead connected to a commercially available ICD positioned in a left pectoral or left lateral location.

The Atala™ lead will be connected to a compatible ICD pulse generator and tested to verify appropriate sensing and defibrillation. Abbreviated IVA testing will be performed at the 3-month follow-up visit to verify continued sensing and defibrillation effectiveness. Starting at 6 months, Subjects will be followed every 6 months until the study is closed. The study is expected to remain open for at least 3 years.

Endpoints will be analyzed and summarized in a final study report after all active Subjects have completed the 3-month visit.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • At least 18 years old
  • Class I or IIa indication for implantation of an ICD according to the ACC/AHA/HRS Guidelines or ESC guidelines

排除标准

  • Participation in any concurrent clinical study without prior written approval from the Sponsor
  • Inability or unwillingness to provide informed consent to participate in the Study
  • Any known conditions which may complicate the AtaCor EV-ICD Lead System implant procedure or prevent the subject from completing protocol testing through the 3-month follow-up visit
  • Circumstances that may prevent data collection or completion of specified follow-up visits
  • Allergies to any device materials listed in the Instructions for Use (IFU)
  • Subjects on anticoagulation therapy that cannot be temporarily discontinued for the procedure
  • Known history of lung disease with FEV1 < 1.0 Liter
  • Device Related:
  • Presence or planned use of medical devices that introduce current into the body (e.g., pacemaker, LVAD, neurostimulator, etc.)
  • Implanted with or planned implantation of any device which delivers current in the body, that may interfere with therapy delivery, including, but not limited to a pacemaker, or neurostimulator
  • Presence or planned use of a subcutaneous ICD lead, subcutaneous coils/arrays, epicardial patches or epicardial pace/sense leads
  • Any known need for future MRI
  • Anatomy Related:
  • BMI ≥ 35 kg/m2
  • Structural abnormalities of the heart that may increase risk of the study procedure or an obstructed/restricted pathway into the mediastinum
  • Prior sternotomy of any type, including but not limited to median, mini or clamshell
  • Prior surgery with disruption of the lung, pericardium or connective tissue between the sternum and pericardium
  • Known significant anatomic derangement of or within the thorax (e.g., pectus excavatum, significant scoliosis) and associated with displacement of the heart or lungs or impeded mediastinal access.
  • History of thoracic radiation therapy, pneumothorax, pneumomediastinum or other medical treatments/conditions which may complicate the AtaCor EV-ICD Lead System implant procedure
  • Known adhesions in the thorax or history of medical treatments, surgeries or conditions that increase the potential for adhesions in the thorax
  • Surgically corrected congenital heart disease (not including catheter-based procedures)
  • Cardiac Related:
  • Subjects who require permanent bradycardia pacing or cardiac resynchronization therapy
  • NYHA IV functional class in past 90 days
  • Inotropic therapy in past 180 days
  • Known history of pericardial disease, pericarditis or mediastinitis
  • Patients with a medical condition that precludes them from undergoing defibrillation testing:
  • Severe aortic stenosis
  • Current Intracardiac LA or LV thrombus
  • Severe proximal three-vessel or left main coronary artery disease without revascularization
  • Hemodynamic instability
  • Unstable angina
  • Recent stroke or transient ischemic attack (within the last 6 months)
  • Known inadequate external defibrillation
  • LVEF < 20%
  • LVEDD >70 mm

结局指标

主要结局

Freedom from major ADEs

时间窗: Through 3 months post-implant

Freedom from major Adverse Device Effects (ADEs)

Successful IVA Test

时间窗: At the time of procedure

Successful induced ventricular arrhythmia (IVA) test in the final system configuration

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验