跳至主要内容
临床试验/NCT06125678
NCT06125678已完成不适用

Correlation and Assessment of Small Bowel Lesion Using Cross Sectional Imaging Techniques Compared to Small Intestinal Contrast Ultrasonography in Known Small Bowel Crohn's Disease(the CACTUS-CD Trial): a Prospective Study

Asian Institute of Gastroenterology, India2 个研究点 分布在 1 个国家目标入组 407 人开始时间: 2023年7月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
407
试验地点
2
主要终点
Change in management decision after cross sectional imaging compared to ultrasound

研究概览

简要总结

Small intestinal contrast ultrasound (SICUS) is a modality of intestinal ultrasound (IUS) which does not require any parenteral administration of contrast agent but requires ingestion of around 500 ml of polyethylene glycol (PEG). SICUS does not involve any radiation. Computed tomography enteroclysis (CTE) requires colonic cleansing using polyethylene glycol (PEG) followed by infusion of 1.5 litres of PEG via a nasal catheter to distend and properly visualise the small intestine. CTE although accurate for assessing response to therapy and transmural healing in small bowel CD is associated with radiation and adds to cost of management. Magnetic resonance enterography (MRE) using PEG followed by 2 liters of oral fluid with mannitol was administered to distend and properly visualize the small intestine. MRE although accurate for assessing response to therapy and transmural healing in small bowel CD is associated with radiation and adds to cost of management. On the other hand, SICUS is relatively non-invasive method of small bowel assessment although the accuracy has not been studied prospectively. An earlier retrospective study in which MRE/CTE and SICUS are done within 3 months of each other, SICUS had identified lesions and complications in patients with CD with high levels of sensitivity, specificity, and accuracy compared to CT-enteroclysis (3). These findings need prospective validation. The accuracy of SICUS may be suboptimal due to constant peristalsis in the small intestine. Hence the investigators planned this study to perform SICUS in patients with small bowel CD who otherwise require a MRE/CTE for disease monitoring on the same day before the procedure with the same PEG preparation. If SICUS findings are found to correlate with MRE/CTE findings intros study, SICUS have the potential to replace other modalities for monitoring of small bowel Crohn's disease (CD) and emerge as a cost-effective, easy alternative. The investigators also want to understand the drawbacks and limitations of SICUS in this scenario.

详细描述

Diagnosis, CD site and patient's management shall be made according generally accepted recommendations(4). SICUS shall be performed in all participants by one independent experienced operator (MAM). Colonic cleansing shall be done on night before the examination with Polyethylene glycol (PEG) solution (1 litre). The participants shall be examined after the ingestion of 375 mL (range 250-500 mL) of polyethylene glycol (PEG) in the morning using a convex transducer (2-6 MHz) and a high frequency linear-array transducer for details (5-14 MHz). Median SICUS duration shall be noted. SICUS shall be performed without any additional charges to the participant. CT-Enteroclysis shall be performed in all participants by one independent experienced operator (UK). A 20G needle shall be placed in an antecubital vein and 8-F nasojejunal catheter with aTeflon-covered guide wire shall be positioned under fluoroscopic guidance with the distal extremely located in the distal duodenum/proximal jejunum. Afterward the patient shall be taken into the CT room where hypodense contrast material (1500 mL of PEG) shall be administered manually with 60-mL syringes, with a constant and continuous injection rate of 150 mL/min followed by a flow rate of 200 mL/min until the maximum tolerance of the patient. Just before the examination participants shall receive a smooth muscle relaxant (N butyl 4 scopolamine) to prevent spasms, achieve uniform small bowel distension, and reduce abdominal discomfort. The study shall be performed by a 64-slice multidetector CT with the following scan parameters: collimation 1.25 mm, table feed 39.37 mm/rot, 120 kV, 300 mAs,pitch 0.984:1, rotation time 0.5 s, time of acquisition 12.5 s, FOV 50 cm, matrix 512x512. After the infusion of PEG, CT scan seal be performed before and after the administration of intravenous iodinated contrast material. The contrast-enhanced study shall be acquired 70s after the administration of contrast material (Ultravist 370, Schering AG, Berlin, Germany). Median CT-Enteroclysis duration shall be recorded. Magnetic Resonance enterography (MRE) shall be performed in all participants by one independent experienced operator. The participant shall be fasted for 4-6 h prior to the study. In adults, 2 liters of oral fluid with mannitol shall be administered to distend the bowel loops. Just before the examination participants shall receive a smooth muscle relaxant (Buscopan) to prevent spasms, achieve uniform small bowel distension, and reduce abdominal discomfort. T2, BTFE(axial and coronal sequence),diffusion weighted imaging (DWI)(Coronal sequence), Post contrast (Axial, Coronals and sagittal sequence) will be taken.Median MRE duration shall be recorded.The site of small bowel involvement, maximal bowel wall thickness and complications like stricture and fistula detected by SICUS and MRE/CTE shall be collected and correlated.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with known small bowel CD beyond reach of standard endoscopy who warrants monitoring of disease status either due to assessment of response to therapy/relapse/new unexplained symptoms, persistent disease activity, prior to switching therapy or deciding on surgical management.

排除标准

  • Obese patients with poor ultrasound window
  • pregnant/lactating mother
  • Not willing for CT or enteroclysis examination
  • Renal insufficiency precluding CT

结局指标

主要结局

Change in management decision after cross sectional imaging compared to ultrasound

时间窗: Day 1

Percentage of patients in which cross sectional imaging changed the management decision

次要结局

  • Agreement for extent of involvement in affected area of small intestine between small intestinal contrast ultasound and cross sectional imaging(Day 1)
  • Correlation between bowel wall thickness in affected area in small intestine between small intestinal contrast ultasonography and cross sectional imaging(Day 1)
  • Agreement for detecting complications between small intestinal contrast ultrasound and cross sectional imaging(Day 1)

研究者

发起方
Asian Institute of Gastroenterology, India
申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验