跳至主要内容
临床试验/NCT03645174
NCT03645174已完成不适用

Fiberoptic-guided Endotracheal Intubation Through Laryngeal Mask Airway in Manikin; Long Endotracheal Tube vs. Aintree Intubating Catheter

Ajou University School of Medicine2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2018年9月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
20
试验地点
2
主要终点
Intubation time

研究概览

简要总结

In difficult airway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option. Aintree catheter is a device to help change LMA to endotracheal tube, but it needs complex and multiple process. Long endotracheal tube can solve this problem of Aintree catheter. The purpose of this study is proving the efficacy of long endotracheal tube compared to Aintree cathter in fiberoptic-guided intubation through LMA.

详细描述

In difficult aiway situation, fiberoptic-guided endotracheal intubation through laryngeal mask airway(LMA) is one of option according to Difficult intubation guidelines. First, insert LMA and insert fiberoptic through LMA. Second, insert endotracheal tube using fiberoptic as a guide. This process has several problem. Removal of LMA is impossible, so there is a risk of dislodging of endotracheal tube.

Aintree catheter is developed to this problem. Insert Aintree catheter through LMA using fiberoptic, and remove LMA, finally insert endotracheal tube throug Aintree catheter. But the problem of this method is that the whole process is complex and takes long time. And there is a risk of impeding of endotracheal tube at glottis level because the difference of diameters between endotracheal tube and aintree catheter.

Long endotracheal tube could solve the problems mentioned above. Through LMA, insert endotracheal tube using fiberoptic as a guide. Tube is long enough to remove LMA without a risk of dislodging. And after removal of LMA, tube can be cut for optimizing length.

So the purpose of this study is comparing the efficacy of Aintree catheter method and Long tube method in manikin.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
20 Years 至 40 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Residents of Anesthesiology
  • Who has less than 10 times of experience of fiberoptic intubation

排除标准

  • Who has more than 10 times of experience of fiberoptic intubation
  • Who deny participating in the study

研究组 & 干预措施

Aintree catheter

Active Comparator

Fiberoptic-guided intubation through LMA, using Aintree catheter

干预措施: Aintree catheter (Device)

Long tube

Experimental

Fiberoptic-guided intubation through LMA, using long tube

干预措施: Using long tube (Device)

结局指标

主要结局

Intubation time

时间窗: 3 minutes

from entry of fiberoptic at LMA to Ambu bagging

次要结局

  • Difficulty score(5 minutes)
  • Success rate(5 minutes)

研究者

发起方
Ajou University School of Medicine
申办方类型
Other
责任方
Principal Investigator
主要研究者

In-kyong Yi

Clinical assitant professor

Ajou University School of Medicine

研究点 (2)

Loading locations...

相似试验