跳至主要内容
临床试验/NCT07398209
NCT07398209招募中不适用

Combining 4D MRI and 4DCT for Personalized Volumetric Motion Monitoring in Lung Radiation Therapy

University of Maryland, Baltimore1 个研究点 分布在 1 个国家目标入组 44 人开始时间: 2026年4月14日最近更新:
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
44
试验地点
1
主要终点
To investigate if time-resolved, multicycle volumetric motion modeling and monitoring gives improved spatiotemporal localization of the tumor target and OARs compared to current standard-of-care 4DCT-based motion modeling and monitoring

研究概览

简要总结

The purpose of this study is to assess a real time motion tracking of lung tumors and important organs next to the tumor while breathing during a participant's radiation treatment. This will be assessed through a four-dimensional magnetic resonance imaging (MRI) scan before starting your radiation treatment and x-ray fluoroscopy images that are taken during radiation

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult (≥18 years) patients (both sexes) with histologically diagnosed Stage II-IIIb NSCLC
  • Patients to be treated with definitive external beam photon radiotherapy with or without systemic therapy (e.g., chemotherapy, immunotherapy).
  • No restrictions on number radiotherapy fractions, or location/number of lesions
  • ECOG performance status ≤ 3
  • Ability to undergo MRI scans
  • Patient has signed informed consent document and agreed to study procedures

排除标准

  • Pre-existing contraindications for MRI, such as any MRI-conditional or MRI-unsafe foreign objects within the body, non-removable ear cochlear or eye implant, aneurysm clip, cardiac pacemaker/wires, internal defibrillator, tissue expander, recent stent placement, penile prosthesis, medication patch, artificial limb, pregnancy, and claustrophobia
  • Women who are pregnant or trying to get pregnant (self-reported)
  • Pain in supine position or inability to raise arm above head in supine position

研究组 & 干预措施

Imaging

Experimental

At baseline, patients will receive a 4D CT Simulation (standard of care) along with a 4D MRI with surface monitoring (research).

During their radiation treatment, they will receive additional fluoroscopy imaging and surface monitoring.

干预措施: MRI (Other)

结局指标

主要结局

To investigate if time-resolved, multicycle volumetric motion modeling and monitoring gives improved spatiotemporal localization of the tumor target and OARs compared to current standard-of-care 4DCT-based motion modeling and monitoring

时间窗: 3 years

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Amit Sawant

Principal Investigator

University of Maryland, Baltimore

研究点 (1)

Loading locations...

相似试验