跳至主要内容
临床试验/NCT03054870
NCT03054870终止3 期

A Comparison of Technegas® and Xenon 133 Planar Lung Imaging in Subjects Referred for Ventilation Scintigraphy

Cyclomedica Australia PTY Limited9 个研究点 分布在 1 个国家目标入组 226 人开始时间: 2017年9月1日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
3 期
状态
终止
入组人数
226
试验地点
9
主要终点
Blinded Readers Percent Agreement (PA) for Matching Image Views

研究概览

简要总结

Phase 3 within-subject non-inferiority trial of Technegas ventilation imaging compared to Xenon-133 (Xe-133) ventilation imaging to demonstrate the non-inferiority of Technegas compared to Xe-133 ventilation studies with respect to subject pulmonary ventilatory distribution. Subjects will undergo site-specific standard of care (SOC) Xe-133 imaging per medical needs followed by Technegas ventilation imaging per study protocol.

详细描述

This is a Phase 3 within-subject non-inferiority trial of Technegas ventilation imaging compared to Xenon-133 (Xe-133) ventilation imaging to demonstrate the non-inferiority of Technegas compared to Xe-133 ventilation studies with respect to subject pulmonary ventilatory distribution. Subjects will undergo site-specific standard of care (SOC) Xe-133 imaging per medical needs followed by Technegas ventilation imaging per study protocol. Primary assessments of efficacy will be based on three blinded readers' assessments of the Technegas and Xe-133 ventilation images in independent reading sessions.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Crossover
主要目的
Other
盲法
None

盲法说明

Independent blinded readers will assess all ventilation scintigraphy images, masked as to subject identity and re-identified with a unique random code number (different code numbers for Xe-133 and Technegas images). The Xe-133 and Technegas images will be read in separate reading sessions in random order.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female subject at least 18 years of age.
  • Subject is a candidate for ventilation imaging.
  • Subject must be willing and able to provide informed consent.
  • Subject must be stable and able to undergo Xe-133 planar imaging and Technegas planar imaging.
  • Subject must be willing and agree to complete study procedures.
  • Subject is using adequate birth control, if female and fertile. Adequate birth control is defined as surgical sterilization, hormone contraceptive use or intrauterine device (IUD).
  • Female subject of child-bearing potential has a negative urine or serum pregnancy test.
  • Subject has had or is scheduled to have a chest X-ray within 24 hours prior to the investigational imaging study.

排除标准

  • Subject has been administered any other radiopharmaceutical within a timeframe that might cause interference with study imaging.
  • Subject is a pregnant or lactating female.
  • Subject has received Technegas in the past.
  • Subject has received an investigational drug within 30 days prior to dosing.
  • Subject is hemodynamically unstable.

研究组 & 干预措施

Xe-133 Followed by Technegas

Other

Subjects first inhaled active comparator Xe-133, approximately 10 to 30 millicuries (mCi), and ventilation planar scintigraphy was performed per site standard of care procedures for subject medical need. On the same day, following completion of Xe-133 imaging, subjects inhaled experimental Technegas (Technetium-99m labeled carbon particles), approximately 1.1 mCi, and ventilation planar scintigraphy was performed.

干预措施: Xe-133 (Drug)

Xe-133 Followed by Technegas

Other

Subjects first inhaled active comparator Xe-133, approximately 10 to 30 millicuries (mCi), and ventilation planar scintigraphy was performed per site standard of care procedures for subject medical need. On the same day, following completion of Xe-133 imaging, subjects inhaled experimental Technegas (Technetium-99m labeled carbon particles), approximately 1.1 mCi, and ventilation planar scintigraphy was performed.

干预措施: Technegas (Drug)

结局指标

主要结局

Blinded Readers Percent Agreement (PA) for Matching Image Views

时间窗: The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).

Three blinded readers independently assessed the Xe-133 and Technegas images in separate reading sessions. Readers were blinded to all clinical information except a subject's screening chest X-ray. Xe-133 images were obtained per site-specific standard of care. Technegas images included a 6-view image set, and the primary endpoint was based on assessment of the subset of views that matched the Xe-133 image views. At the start of each case-read, a reader visually divided each lung into 3 regions of approximately equal size arranged craniocaudally (apical, mid, and basal), 6 regions in total, and then assessed each lung region for ventilation according to a three-point scale: 0=absent ventilation, 1=decreased ventilation, 2=normal ventilation. At the unplanned interim stage, PA between the Xe-133 scores and Technegas scores was tested for non-inferiority at one-sided alpha=0.0141, equivalent to the lower bound of the 97.18% confidence interval exceeding 60%.

次要结局

  • Percent Agreement Measuring Inter-observer Agreement(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)
  • Blinded Readers Percent Agreement (PA) for All Image Views(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)
  • Kappa Statistics Between Pairs of Blinded Readers by Lung Region(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (9)

Loading locations...

相似试验

进行中(未招募)
不适用
Comparison of the diagnostic efficacy of Xenetix 350 and Iomeron 400, for visualisation of the aorta and abdominal vascular tree with 64-slices computed tomographyPatients scheduled for an abdominal MSCT angiography.MedDRA version: 9.0Level: LLTClassification code 10063983
EUCTR2006-001298-57-ATGUERBET310
进行中(未招募)
不适用
Comparison of the diagnostic efficacy of Xenetix 350 and Iomeron 400, for visualisation of the aorta and abdominal vascular tree with 64-slices computed tomographyPatients scheduled for an abdominal MSCT angiography.MedDRA version: 9.0Level: LLTClassification code 10063983
EUCTR2006-001298-57-DEGUERBET310
进行中(未招募)
不适用
Comparison of the diagnostic efficacy of Xenetix 350 and Iomeron 400, for visualisation of the aorta and abdominal vascular tree with 64-slices computed tomographyPatients scheduled for an abdominal MSCT angiography.MedDRA version: 9.0Level: LLTClassification code 10063983
EUCTR2006-001298-57-BEGUERBET310
进行中(未招募)
不适用
Comparison of the diagnostic efficacy of Xenetix 350 and Iomeron 400, for visualization of the aorta and abdominal vascular tree with 64-slices computed tomography. - ISO-44-009Patients scheduled for an aorta and abdominal arterial tree evaluation by MSCT, either for pretherapeutic evaluation or for post-surgical control or follow up (including patients with prosthetic vascular material).MedDRA version: 9.1Level: LLTClassification code 10052677Term: Vascular imaging
EUCTR2006-001298-57-ITGUERBET310
终止
3 期
Compare Technegas Ventilation-Perfusion SPECT and Xenon Ventilation-Perfusion Planar Imaging for Pulmonary EmbolismPulmonary Embolism
NCT01458639Cyclomedica Australia PTY Limited18