A Comparison of Technegas® and Xenon 133 Planar Lung Imaging in Subjects Referred for Ventilation Scintigraphy
试验速览
- 阶段
- 3 期
- 状态
- 终止
- 入组人数
- 226
- 试验地点
- 9
- 主要终点
- Blinded Readers Percent Agreement (PA) for Matching Image Views
研究概览
简要总结
Phase 3 within-subject non-inferiority trial of Technegas ventilation imaging compared to Xenon-133 (Xe-133) ventilation imaging to demonstrate the non-inferiority of Technegas compared to Xe-133 ventilation studies with respect to subject pulmonary ventilatory distribution. Subjects will undergo site-specific standard of care (SOC) Xe-133 imaging per medical needs followed by Technegas ventilation imaging per study protocol.
详细描述
This is a Phase 3 within-subject non-inferiority trial of Technegas ventilation imaging compared to Xenon-133 (Xe-133) ventilation imaging to demonstrate the non-inferiority of Technegas compared to Xe-133 ventilation studies with respect to subject pulmonary ventilatory distribution. Subjects will undergo site-specific standard of care (SOC) Xe-133 imaging per medical needs followed by Technegas ventilation imaging per study protocol. Primary assessments of efficacy will be based on three blinded readers' assessments of the Technegas and Xe-133 ventilation images in independent reading sessions.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- None
盲法说明
Independent blinded readers will assess all ventilation scintigraphy images, masked as to subject identity and re-identified with a unique random code number (different code numbers for Xe-133 and Technegas images). The Xe-133 and Technegas images will be read in separate reading sessions in random order.
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Male or female subject at least 18 years of age.
- •Subject is a candidate for ventilation imaging.
- •Subject must be willing and able to provide informed consent.
- •Subject must be stable and able to undergo Xe-133 planar imaging and Technegas planar imaging.
- •Subject must be willing and agree to complete study procedures.
- •Subject is using adequate birth control, if female and fertile. Adequate birth control is defined as surgical sterilization, hormone contraceptive use or intrauterine device (IUD).
- •Female subject of child-bearing potential has a negative urine or serum pregnancy test.
- •Subject has had or is scheduled to have a chest X-ray within 24 hours prior to the investigational imaging study.
排除标准
- •Subject has been administered any other radiopharmaceutical within a timeframe that might cause interference with study imaging.
- •Subject is a pregnant or lactating female.
- •Subject has received Technegas in the past.
- •Subject has received an investigational drug within 30 days prior to dosing.
- •Subject is hemodynamically unstable.
研究组 & 干预措施
Xe-133 Followed by Technegas
Subjects first inhaled active comparator Xe-133, approximately 10 to 30 millicuries (mCi), and ventilation planar scintigraphy was performed per site standard of care procedures for subject medical need. On the same day, following completion of Xe-133 imaging, subjects inhaled experimental Technegas (Technetium-99m labeled carbon particles), approximately 1.1 mCi, and ventilation planar scintigraphy was performed.
干预措施: Xe-133 (Drug)
Xe-133 Followed by Technegas
Subjects first inhaled active comparator Xe-133, approximately 10 to 30 millicuries (mCi), and ventilation planar scintigraphy was performed per site standard of care procedures for subject medical need. On the same day, following completion of Xe-133 imaging, subjects inhaled experimental Technegas (Technetium-99m labeled carbon particles), approximately 1.1 mCi, and ventilation planar scintigraphy was performed.
干预措施: Technegas (Drug)
结局指标
主要结局
Blinded Readers Percent Agreement (PA) for Matching Image Views
时间窗: The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).
Three blinded readers independently assessed the Xe-133 and Technegas images in separate reading sessions. Readers were blinded to all clinical information except a subject's screening chest X-ray. Xe-133 images were obtained per site-specific standard of care. Technegas images included a 6-view image set, and the primary endpoint was based on assessment of the subset of views that matched the Xe-133 image views. At the start of each case-read, a reader visually divided each lung into 3 regions of approximately equal size arranged craniocaudally (apical, mid, and basal), 6 regions in total, and then assessed each lung region for ventilation according to a three-point scale: 0=absent ventilation, 1=decreased ventilation, 2=normal ventilation. At the unplanned interim stage, PA between the Xe-133 scores and Technegas scores was tested for non-inferiority at one-sided alpha=0.0141, equivalent to the lower bound of the 97.18% confidence interval exceeding 60%.
次要结局
- Percent Agreement Measuring Inter-observer Agreement(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)
- Blinded Readers Percent Agreement (PA) for All Image Views(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)
- Kappa Statistics Between Pairs of Blinded Readers by Lung Region(The median duration of Technegas imaging was 22 minutes. Blinded reader assessments of images ranged from <1 month to 16 months following the imaging (median 5 months).)