Investigation of the Effect of Plantar Fascia Release With Magnetic Fascia Ball on Hamstring and Lumbar Spine Flexibility
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 32
- 试验地点
- 2
- 主要终点
- Goniometric Measurement of Hamstring Flexibility
研究概览
简要总结
In this study, the effect of plantar fascia release with a magnetic fascial cork ball on hamstring and lumbar extensor muscle elasticity will be investigated.
详细描述
The use of tools such as foam rollers or massage balls to resolve myofascial tension is highly preferred by both therapists and patients. It is theorized that the sweeping pressure generated during rolling causes the fascia to stretch and increase the range of motion. In addition, the warming caused by the friction during rolling can dissolve the adhesions between the fascial layers and restore the elasticity of the myofascial tissues. In addition to similar mechanical effects, the use of cork balls with magnetic properties is becoming increasingly common. Studies have shown that static magnetic magnets reduce pain, increase microcirculation and oxygenation and cause changes in presynaptic membrane function. As far as we know, there is no study examining the myofascial relaxation effect of magnetic balls in the literature. Evaluating the clinical impact and efficacy of this device which allow the person to perform self-massage might contribute the current literature. This study was planned to evaluate the myofascial relaxation caused by two different fascial cork balls with and without magnetic properties.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Double (Participant, Outcomes Assessor)
入排标准
- 年龄范围
- 18 Years 至 35 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •Having scored 3 or less according to the Beighton scoring system
- •18-35 years old,
- •Having asymptomatic
- •Voluntary participation in the research
排除标准
- •Having Beighton score of 4 and above
- •Having history of previous surgery
- •Having diagnosed pathology of the lower extremities and lumbar region
结局指标
主要结局
Goniometric Measurement of Hamstring Flexibility
时间窗: Two times in one day (before intervention, immediately after intervention)
Individuals are positioned supine with the hip of the limb to be measured at 90 degrees. In this position, active knee extension is requested and the acute angle between the long axis of the femur and the long axis of the fibula is measured. The DrGonyometer (iOS) smart phone application, for which a validity and reliability study was conducted, was used for the measurement.
次要结局
- Sit and reach test(Two times in one day (before intervention, immediately after intervention))
研究者
Ömer Osman Pala
Assistant Professor
Abant Izzet Baysal University
