跳至主要内容
临床试验/NCT03726203
NCT03726203已完成不适用

Benign Gynecologic Laparoscopic Surgery: Comparison of Conventional Trocars to the Teleflex® MiniLap® System in Length of Hospitalization, Pain and Aesthetics, a Randomized Study.

University Hospital, Lille1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2019年1月15日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
50
试验地点
1
主要终点
The time required to validate the Marshall and Chung criteria authorizing outpatient discharge when using the Minilap® system in comparison to the use of conventional trocars.

研究概览

简要总结

During laparoscopy, trocars are essential: they allow the passage of instruments through the wall. In gynecology, with exception, trocars 5mm (used for the passage of endo-scissors and forceps) and 10 to 12mm are used (especially for optics).

Trocars are responsible for complications, such as vascular wounds, digestive wounds, pain, infections or postoperative hernias, or aesthetic sequelae, and should be chosen with caution: most complications of laparoscopy are essentially due to their placement, and the complications at the introduction of the first trocar are the most frequent.

The MiniLap® system developed by Teleflex does not require trocars in the case of a single forceps, or a single 5mm trocar with the necessary forceps change (this is the Percuvance® system). The aim of the latter is to make minimally invasive surgery even less invasive, thanks to a reduction in the number of trocars used (in many cases, elimination of two trocars), smaller incisions (percutaneous use of instruments, with a diameter of 2,4mm) thus reducing the complications

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • BMI <35kg / m2
  • No history of multiple abdominopelvic surgery
  • Without absolute contraindication to laparoscopy
  • In the context of ambulatory surgery
  • With precise laparoscopy of indication:
  • Exploratory or diagnostic
  • Exploration of infertility
  • Performing a tubal permeability test
  • Performing a salpingectomy
  • Realization of a tubal sterilization
  • Realization of a tubal plasty
  • Performing an ovariectomy
  • Performing a simple ovarian cystectomy
  • Patient have been informed during her preoperative consultation and have signed the consent in a free and informed manner upon admission to hospital

排除标准

  • Performing an emergency surgery
  • Carcinological surgery
  • Performing a benign but complex surgery such as:
  • Hysterectomy
  • Prolapse cure
  • promontofixation
  • Complex surgery of endometriosis
  • Removal of large cyst from the ovary.
  • Person unable to receive informed information and / or give consent. Person deprived of liberty.
  • Pregnant or nursing woman.

结局指标

主要结局

The time required to validate the Marshall and Chung criteria authorizing outpatient discharge when using the Minilap® system in comparison to the use of conventional trocars.

时间窗: at the end of surgery, an average 3 hours

次要结局

  • of the intraoperative use of the trocar system using a questionnaire to be completed by the surgeon(At immediate postoperative (baseline,1 hour and 3 hours))
  • Pain using the Visual Analog Scale (VAS)(at immediate postoperative (baseline,1 hour and 3 hours) and postoperative visit (6 weeks ± 1 after surgery).)
  • Aesthetic scars using a scale of 0 to 10(postoperative visit (6 weeks ± 1 after surgery).)
  • number of complication per operative(At immediate postoperative (baseline,1 hour and 3 hours))
  • post-operative complications at the level of the trocar apertures using a questionnaire(at immediate postoperative (baseline,1 hour and 3 hours) and postoperative visit (6 weeks ± 1 after surgery).)

研究者

发起方
University Hospital, Lille
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验