The Influence of the Different Ways of Pneumatic Compression on Clinical and Physiologic Efficacies in Preventing Deep Vein Thrombosis: a Randomised Comparative Study

Seoul National University Hospital2 个研究点 分布在 2 个国家目标入组 54 人开始时间: 2012年3月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
54
试验地点
2
主要终点
Rate of Deep Vein Thrombosis

研究概览

简要总结

Various kinds of intermittent pneumatic compression devices (IPC) with particular ways of compression have been developed and used for prevention of deep vein thrombosis.

There are still some controversies about the physiologic properties and clinical impact of numerous issues including the variety of the cuff length, inflation rate, compression sequence, compression-relaxation cycle rate, and pressure generation characteristics.

This study is designed to compare clinical efficacies as well as venous hemodynamic improvements between Simultaneous bilateral compression with fixed venous refill time versus alternate compression with adjusted refill time

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Participant)

入排标准

性别
All
接受健康志愿者

入选标准

  • the patients who undergo total knee replacement arthroplasty

排除标准

  • (1) chronic superficial or deep venous insufficiency, (2) venous anomalies like duplication of the superficial femoral vein, (3) previous venous thromboembolism history, (4) being under anticoagulation therapy, (5) severe arteriosclerosis obliterans without palpable dorsalis pedis pulse, (6) open fracture, hemorrhagic condition, or extensive dermatitis at lower legs, (7) congestive heart failure. Additional exclusion criteria included a documented malignant tumor, because pharmacologic prophylaxis with anticoagulants would be more reasonable in this case.

研究组 & 干预措施

Simultaneous compression+Fixed refill time

Active Comparator

Simultaneous bilateral compression with fixed venous refill time through the whole duration of pneumatic compression

干预措施: DVT-3000 (Device)

Alternate compression+Adjusted refill time

Active Comparator

alternate bilateral compression with adjusted venous refill time which would change several times during pneumatic compression

干预措施: SCD Express (Device)

结局指标

主要结局

Rate of Deep Vein Thrombosis

时间窗: On 4th postoperative days after total knee replacement arthroplasty

Computed tomographic angiography were performed on 4th postoperative days to detect deep vein thrombosis and evaluate its extent and location.

次要结局

  • Total Volume Flow(On 4th postoperative days after total knee replacement arthroplasty)
  • Augmented PV(On 4th postoperative days after total knee replacement arthroplasty)
  • Augmented PVF(On 4th postoperative days after total knee replacement arthroplasty)
  • Augmented TVF(on 4th postoperative day after total knee replacement arthroplasty)
  • Peak Velocity(On 4th postoperative days after total knee replacement arthroplasty)
  • Mean Velocity(On 4th postoperative days after total knee replacement arthroplasty)
  • Expelled Total Volume(On 4th postoperative days after total knee replacement arthroplasty)
  • Augmented MV(On 4th postoperative days after total knee replacement arthroplasty)
  • Cycling Rate(on 4th postoperative day after total knee replacement arthroplasty)
  • Peak Volume Flow(On 4th postoperative days after total knee replacement arthroplasty)
  • Expelled Peak Volume(On 4th postoperative days after total knee replacement arthroplasty)