跳至主要内容
临床试验/NCT01683474
NCT01683474Unknown不适用

Clinical Evaluation of the Safety and Performance of Percutaneous Implantation of the Venus MedTech Aortic Valve Prosthesis for Patients Who Cannot Undergo Surgical Valve Replacement

Venus MedTech (HangZhou) Inc.1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2012年9月最近更新:
适应症

试验速览

阶段
不适用
入组人数
80
试验地点
1
主要终点
All cause mortality and major stroke at 12 months post-procedure.

研究概览

简要总结

  1. objectives
  • Evaluate the performance of Venus MedTech aortic valve prosthesis intervention by femoral artery
  • Evaluate safety and clinical benefit of percutaneous implantation of the Venue MedTech aortic valve prosthesis.
  • Continuous observe 12 months of safety and efficacy.
  1. Approximately 80 patients presenting with native aortic valve stenosis necessitating valve replacement which are considered unsuitable for Surgical Valve Replacement, with a high surgical risk, as attested to by both the surgeon and the cardiologist are recruited in the study.
  2. Safety and performance will be evaluated at discharge and at 30 days post procedure. Valve safety, performance and placement will be followed up at 6 and 12 months post-procedure.

详细描述

A prospective OPC study to evaluate its performance and long-term safety and effectiveness of Venus-A aortic valve.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Senile degenerative aortic valve stenosis with echocardiography derived criteria: mean gradient ≥ 40 mm Hg, or jet velocity ≥ 4.0 m/s, or an aortic valve area (AVA) of < 0.8 cm2 (or AVA index < 0.5 cm2/m2)
  • Symptomatic due to aortic valve stenosis as demonstrated by NYHA Functional Class ≥ II
  • The subject or the subject's legal representative was informed of the nature of the study, agreed to its provisions and provided written informed consent as approved by the Institutional Review Board of the respective clinical site.
  • The subject agreed to comply follow-up evaluation
  • is evaluated by at least one cardiologist and two cardiovascular surgeon, and they agreed that medical factors precluding operation suitable for surgery (the probability of death or serious, irreversible morbidity exceeded 50%)
  • STS score ≥ 10%

排除标准

  • Patient refuses aortic valve replacement surgery.
  • Evidence of an acute myocardial infarction ≤ 1 month before the intended treatment [defined as: Q wave MI, or non-Q wave MI with total CK elevation of CK-MB ≥ twice normal in the presence of MB elevation and/or troponin level elevation (WHO definition)].
  • Aortic valve is a congenital unicuspid or congenital bicuspid valve, or is non-calcified.
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation >3+).
  • Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days (6 month if DES implant)
  • Implanted any heart valve prosthesis, prosthetic valve ring, severe mitral valve ring calcification (MAC), severe(>3+)mitral valve insufficiency, or Gorelin symptom
  • Blood dyscrasia such as leukopenia (WBC < 3×109/L), acute anemia (Hgb < 90 g/L), thrombocytopenia (PLT < 50×109/L), bleeding diathesis, or history of coagulopathy.
  • Untreated clinically significant coronary artery disease requiring revascularization
  • Hemodynamic instability requiring inotropic therapy or mechanical hemodynamic support devices
  • Need for emergency surgery for any reason
  • Hypertrophic cardiomyopathy with or without obstruction (HOCM)
  • Severe ventricular dysfunction with LVEF < 20%
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  • Active peptic ulcer or upper gastro-intestinal bleeding within the prior 3 months
  • A known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated.
  • Native aortic annulus size < 20 mm or> 29 mm as measured by echocardiogram.
  • Cerebrovascular Accident (CVA) within 6 months, including TIA.
  • Renal insufficiency (creatinine > 3.0 mg/dL) and/or end stage renal disease requiring chronic dialysis.
  • Life expectancy < 12 months
  • Significant abdominal or thoracic aorta disease, including aneurysm (defined as maximal luminal diameter 5cm or greater), marked tortuosity (hyperacute bend), aortic arch atheroma (especially if thick [> 5 mm], protruding or ulcerated), narrowing of the abdominal aorta (especially with calcification and surface irregularities), or severe "unfolding" and tortuosity of the thoracic aorta
  • Iliofemoral vessel characteristics that would preclude safe placement of 16F or 18F introducer sheath such as severe obstructive calcification, severe tortuosity or vessel size diameter < 7 mm.
  • Currently participating in an investigational drug or another device study.
  • Active bacterial endocarditis or other active infections.
  • Bulky calcified aortic valve leaflets in close proximity to coronary ostia

结局指标

主要结局

All cause mortality and major stroke at 12 months post-procedure.

时间窗: 12 months post-procedure

次要结局

  • Valve performance and placement at 6 and 12 months post-procedure(6 and 12 months post-procedure)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验