A Device to Prevent Sudden Unexpected Death in Epilepsy: Detecting Peri-Ictal Body Position

Brigham and Women's Hospital1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2026年8月15日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
50
试验地点
1
主要终点
Body position detection

研究概览

简要总结

The goal of this study is to assess the performance of a commercial sheet sensor in determining body position after generalized tonic-clonic (GTC) seizures. If a sheet sensor could accurately detect GTC seizures, this could be a step towards autonomously repositioning patients with the aid of a smart mattress.

Primary Objective

Milestones:

Feasibility objective: Monitor 50 patients with the objective of capturing at least 20 GTCS events. Primary analytic objective: Achieve detection of anatomical landmarks with body position change within 5 seconds with an accuracy of 75% both interictally and post-GTCS.

Secondary Objective Detect the postictal prone position with an accuracy of 100%.

详细描述

This is an exploratory study with the goal of using a commercial bed sheet sensor and software with Soterya Inc's Korus software to identify GTCs in an inpatient setting.

50 patients will be monitored at the BWH EMU with the goal of capturing 20 GTCS events.

The sheet sensor used will be the Sensor Products Tactilus High Performance Mattress Sensor System with the accompanying Tactilus Software. Pressure sensor data will be processed by Soterya Inc's Korus Software. The sensor system is a piezoresistive device that is already in commercial use.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Device Feasibility
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 1. Adults 18 years of age or older admitted to the BWH EMU with drug-resistant epilepsy, defined by the failure of at least two anti-seizure medications and a documented history of electroclinical seizures

排除标准

  • Suspicion of functional dissociative seizures (psychogenic nonepileptic seizures)
  • Patients admitted for medication adjustment only

结局指标

主要结局

Body position detection

时间窗: 5 seconds

Correct detection of one of 4 cardinal body positions: prone, supine, left, right

Number of subjects correctly repositioned from the prone to recovery position

时间窗: 30 seconds

We will measure the performance of Korus to successfully reposition the subject from the prone to recovery position

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Jong Woo Lee

Associate Professor of Neurology

Brigham and Women's Hospital

研究点 (1)