跳至主要内容
临床试验/NCT05999760
NCT05999760已完成不适用

Retention, Chewing Efficiency and Masticatory Performance of Maxillary Flexible Versus Computer Aided Design/Computer Aided Manufacture(CAD/CAM) Partial Dentures Opposing Fixed Implant Retained Prosthesis.

National Research Centre, Egypt1 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2022年11月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
1
主要终点
evaluation of change of retention of versacrylic and CAD/CAM partial denture

研究概览

简要总结

This study aims to evaluate retention ,chewing efficiency and masticatory performance of flexible versus CAD/CAM partial dentures opposing to fixed implant retained restorations.

详细描述

in this study 22 patients will be selected following inclusion and exclusion criteria. The patients will be divided randomly into two groups.

Group I patients will receive Versacrylic removable partial denture. group II patients will receive CAD/CAM removable partial denture all patients will be given the home care instructions at night and brush cleaning of the dentures.

Measurements of retention using universal testing machine, masticatory performance using T-scan III computerized system and chewing efficiency using chewing function questionnaire

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

盲法说明

each patient was not informed about material of received prosthesis

入排标准

年龄范围
40 Years 至 50 Years(Adult)
性别
Male
接受健康志愿者
否

入选标准

  • •Non-smoker male Patients
  • •Age ranging from 40-50 years.
  • •Highly cooperative and motivated patients.
  • •Patients Systemically free from any immunosuppressive diseases.
  • •Patients free from Diabetes, Hypertension, Cancer, any mental or physical diseases.
  • •Patients not receiving any Radiotherapy or chemotherapy treatment.

排除标准

  • •Female patients
  • •Smoker patients.
  • •Age exceeding 50 years
  • •Uncooperative and unmotivated patients.

研究组 & 干预措施

Group I (patients received Versacryle removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary Versacryle removable partial denture

干预措施: evaluation of retention of Versacryle and CAD/CAM partial dentures by force gauge (Device)

Group I (patients received Versacryle removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary Versacryle removable partial denture

干预措施: chewing efficiency by electromyograph(E.M.G) (Device)

Group I (patients received Versacryle removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary Versacryle removable partial denture

干预措施: masticatory performance(questionnaire) (Other)

Group II (patients received CAD/CAM fabricated removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary CAD/CAM fabricated removable partial denture

干预措施: evaluation of retention of Versacryle and CAD/CAM partial dentures by force gauge (Device)

Group II (patients received CAD/CAM fabricated removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary CAD/CAM fabricated removable partial denture

干预措施: chewing efficiency by electromyograph(E.M.G) (Device)

Group II (patients received CAD/CAM fabricated removable partial denture)

Active Comparator

patients having Kennedy class I received maxillary CAD/CAM fabricated removable partial denture

干预措施: masticatory performance(questionnaire) (Other)

结局指标

主要结局

evaluation of change of retention of versacrylic and CAD/CAM partial denture

时间窗: on day 1 ,1 month and 2months of prosthesis delivery

measurement of retention of partial dentures made of Versacryle and CAD/CAM technology

evaluation of change of masticatory performance of versacrylic and CAD/CAM partial denture

时间窗: on day 1,1 month and 2months of prosthesis delivery

measurement of masticatory performance of partial dentures made of Versacryle and CAD/CAM technology

evaluation of change of chewing efficiency of versacrylic and CAD/CAM partial denture

时间窗: on day 1 ,1 month and 2months of prosthesis delivery

measurement of chewing efficiency of partial dentures made of Versacryle and CAD/CAM technology

次要结局

未报告次要终点

研究者

发起方
National Research Centre, Egypt
申办方类型
Other
责任方
Principal Investigator
主要研究者

Menatallah Mohamed Elhotieby

Principle investigator Researcher fixed and removable prosthodontics

National Research Centre, Egypt

研究点 (1)

Loading locations...

相似试验