临床试验/NCT06814262
NCT06814262已完成不适用

Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors

Virginia Commonwealth University1 个研究点 分布在 1 个国家目标入组 28 人开始时间: 2025年3月31日最近更新:
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
28
试验地点
1
主要终点
Determine which of three different attachment sizes offers more predictable extrusion of maxillary lateral incisors in subjects treated with clear aligners compared

研究概览

简要总结

Orthodontic treatment has been revolutionized by clear aligner therapy, offering patients a more esthetic and comfortable alternative to traditional braces. In 1999, Align Technology introduced Invisalign. As Invisalign has increased in popularity and demand over the past two decades, clinical trials have shed light on the efficacy of Invisalign treatment. there have been changes in the Invisalign protocol such as introduction of SmartForce features in 2008, such as optimized attachments as well as the implementation of SmartTrack aligner material in 2011. Compared to conventional fixed orthodontic appliances, Invisalign cannot be adjusted on a visit-to visit basis. If ideal tooth movement has not been achieved after completion of the first sequence of aligners, additional trays, known as refinement trays, are required.

详细描述

There are various expert theories regarding the most effective methods of extrusion and multiple studies performed in vitro to evaluate the efficacy of different attachment types on the extrusion of lateral incisors, however only one in vivo clinical trial exists. There is a need for more randomized clinical trials that evaluate the effectiveness of different attachment designs for achieving optimal extrusion of lateral incisors. By determining the most effective attachment size for maxillary lateral incisor extrusion, this study can help improve treatment outcomes for orthodontic treatment with clear aligners and serve as a guide to assist clinicians in selecting the most effective attachment design.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
12 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients treated with either Comprehensive Invisalign or Invisalign Teen treatment
  • The maxillary arch has less than 6 mm of crowding or spacing
  • Maxillary lateral incisors have a minimum of 0.3 mm of extrusion prescribed in the Tooth Movement Table on the Invisalign ClinCheck for the first set of aligners
  • Maxillary lateral incisors within a normal range of bucco-lingual inclination
  • Patients 12 years of age or older and either the patient or legal guardian are able to give consent
  • Patients confirm good compliance throughout the study period

排除标准

  • Patients do not complete all aligners in the first phase as prescribed
  • Poor compliance recorded for aligner wear
  • Restorations placed or oral surgery completed prior to final scan
  • Midcourse intervention to improve tracking such as a bootstrap
  • Maxillary lateral incisors not tracking and noted by minimum of 1 mm of aligner material incisally displaced when aligner fully seated
  • Treatment plans include surgery or extractions
  • Maxillary lateral incisors with pathology and restorations
  • Missing teeth other than third molars
  • Patients with anterior crossbite

研究组 & 干预措施

Gingivally beveled 1x1x3mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x3mm

干预措施: Superimposition of final and initial positions of lateral incisors: Gingivally beveled 1x1x3mm aligners (Device)

Control/optimized for extrusion.aligners

Placebo Comparator

The control will be Invisalign's optimized attachment which will be specifically optimized for extrusion.

干预措施: Corresponding treatment order in the prescription with Align Technology (Device)

Gingivally beveled 1x1x3mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x3mm

干预措施: Corresponding treatment order in the prescription with Align Technology (Device)

Control/optimized for extrusion.aligners

Placebo Comparator

The control will be Invisalign's optimized attachment which will be specifically optimized for extrusion.

干预措施: Superimposition of final and initial positions of lateral incisors: Predicted model (Device)

Gingivally beveled 1x1x4mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x4mm

干预措施: Corresponding treatment order in the prescription with Align Technology (Device)

Gingivally beveled 1x1x4mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x4mm

干预措施: Superimposition of final and initial positions of lateral incisors: Gingivally beveled 1x1x4mm aligners (Device)

Gingivally beveled 1x1x5mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x5mm

干预措施: Corresponding treatment order in the prescription with Align Technology (Device)

Gingivally beveled 1x1x5mm aligners

Experimental

Each set of aligners would be worn for a week/gingivally beveled 1x1x5mm

干预措施: Superimposition of final and initial positions of lateral incisors: Gingivally beveled 1x1x5mm aligners (Device)

结局指标

主要结局

Determine which of three different attachment sizes offers more predictable extrusion of maxillary lateral incisors in subjects treated with clear aligners compared

时间窗: baseline until the clear aligner treatment is completed at 20 to 25 weeks

The aim of this prospective, randomized controlled trial is to determine which of three different attachment sizes (gingivally beveled 1x1x3 mm, gingivally beveled 1x1x4 mm, or gingivally beveled 1x1x5 mm) offers more predictable extrusion of maxillary lateral incisors in patients treated with clear aligners compared to control.

次要结局

  • Evaluate the accuracy of ClinCheck software(baseline until the clear aligner treatment is completed at 20 to 25 weeks)