跳至主要内容
临床试验/NCT05677568
NCT05677568Enrolling By Invitation不适用

The CINCH-FMR Post-Market Registry: Percutaneous Repair in Functional Mitral Regurgitation

Cardiac Dimensions, Inc.19 个研究点 分布在 1 个国家目标入组 250 人开始时间: 2017年6月24日最近更新:
适应症

试验速览

阶段
不适用
状态
Enrolling By Invitation
发起方
入组人数
250
试验地点
19
主要终点
Death

研究概览

简要总结

This is a retrospective and prospective, multi-center, post-market observational registry study. The primary objective of this post market registry is to continue to evaluate the long term safety and performance of the Carillon® Mitral Contour System® (CMCS) in a commercial (post market) setting.

详细描述

There are more than 22 million people worldwide with heart failure, including 5.3 million in the United States . Functional mitral regurgitation (MR), leakage of the mitral valve due to dilation of the left ventricle and annulus, occurs as a consequence of Heart Failure. Cardiac Dimensions has developed proprietary technology designed to address functional mitral regurgitation in a minimally invasive manner.

Previous studies have established that the Carillon® therapy has caused a significant reduction in functional MR. This reduction in MR results in clinically significant improvements in exercise tolerance, quality of life, and thus overall function in a symptomatic heart failure population.

To supplement the findings from these previous studies, Cardiac Dimensions is conducting this post-market registry of the Carillon® Mitral Contour System® (CMCS) in patients with functional mitral regurgitation. This registry is a retrospective and prospective, multi-center, clinical registry designed to further characterize the acute and long-term safety and performance profile of the CMCS. Up to 250 implanted patients will be enrolled at up to 40 centers located in the European Union and countries that recognize the CE-mark as a valid marketing authorization.

Patients enrolled in the registry have received the Carillon implant and will be assessed to document the long-term safety and performance of the device. These patients will be followed according to routine standard of care post procedure follow up assessments.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Other

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with functional mitral regurgitation (i.e., dilated cardiomyopathy), in accordance with CE-mark approved labeling
  • Patients implanted with the Carillon device
  • Patients must be ≥ 18 years old
  • Patients require informed consent prior to inclusion in this registry
  • Minimum baseline data, as described in CINCH Protocol, including:
  • Hemodynamic measures (by echocardiography)
  • Baseline must include the following measurements: MR grade, LVEF (%), LVEDD, LAD, and AP & ML diameters
  • NYHA Classification

排除标准

  • 未提供

结局指标

主要结局

Death

时间窗: 5 years

All cause mortality including cardiovascular and non-cardiovascular death

Change in New York Heart Association (NYHA) classification

时间窗: 6, 12, and 24 months, and 3, 4, and 5 years

Change in New York Heart Association (NYHA) Functional Classification at 6, 12, and 24 months, and 3, 4, and 5 years

Rate of Heart Failure Hospitalizations

时间窗: 5 years

Rate of hospitalization for heart failure

Serious adverse events

时间窗: 12 months

Number of procedure related or device related serious adverse events

次要结局

  • Change of MR Severity via Quantitative MR Variable: regurgitant fraction (%)(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change of MR severity: Semi-Quantitative Parameter: Change in vena contract width(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change of MR Severity via Quantitative MR Variable: effective regurgitant orifice area (cm2 EROA)(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change of MR severity: Semi-Quantitative Parameter: Change in MV EVmax.(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Atrial Volume Index(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change in Quality-of-Life Overall Score(6,12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Atrial Area(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change of MR Severity via Quantitative MR Variable: regurgitant volume (mL)(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Ventricular End Ejection Fraction (LVEF)(6,12, and 24 months, and 3, 4, and 5 years)
  • Change of MR severity: Semi-Quantitative Parameter: Change in pulmonary vein flow.(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Atrial Diameter(6, 12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Ventricular End Systolic Volume (LVESV)(6,12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Ventricular End Diastolic Volume (LVEDV)(6,12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Ventricular End Systolic Diameter (LVESD)(6,12, and 24 months, and 3, 4, and 5 years)
  • Change in Left Ventricular End Diastolic Diameter (LVEDD)(6,12, and 24 months, and 3, 4, and 5 years)
  • Change in exercise tolerance by walking(6,12, and 24 months, and 3, 4, and 5 years)

研究者

发起方
Cardiac Dimensions, Inc.
申办方类型
Industry
责任方
Sponsor

研究点 (19)

Loading locations...

相似试验