A Comparative Study of the Results of Dynamic and OPD Static Measurement of Pupil Diameter Before and After Cataract Surgery by Pupil Detectors

Shanghai Eye Disease Prevention and Treatment Center0 个研究点目标入组 60 人开始时间: 2024年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
60
主要终点
pupil size

研究概览

简要总结

Age-related cataract remains the leading cause of blindness in developing countries. And, with the aging of the population in these countries, the number of cataract patients will continue to grow. With accurate biological measurements and the implantation of a suitable IOL, most cataract patients can achieve good distance vision after surgery. Studies have shown differences in pupil diameter and sensitivity in patients with different refractive states, with correlations to accommodation status as well as refractive error. The pupil is an important factor to be evaluated during the selection of an artificial lens (Intraocular lens, IOL), especially a functional IOL.

Among the various instruments used for preoperative cataract biological measurements, the light source is mostly a fixed parameter, and the static pupil diameter measurement by fixed illumination light source detection as an evaluation method is relatively rough. In this study, we are going to simulate different illumination states in daily life and set up two kinds of measurement instruments, namely, OPD and binocular pupil detector, so as to obtain more realistic research results and to explore the following: 1. The static and dynamic measurement of pupil diameter by people of different refractive states in different periods of preoperative and postoperative period. 2. Whether there is a difference between the static and dynamic pupil measurement results, 2. the change of pupil size under the stimulation of different light sources, and to compare the difference between the two detection methods, to provide objective pupil indexes for the more scientific selection of functional IOLs, to provide a basis for the selection of more accurate pupil measurement methods, to accurately screen the population of the use of functional IOLs, and to improve the patient's satisfaction after the operation.

Purpose of the study To simulate the difference between the preoperative and postoperative pupil diameters of cataract patients measured by static and dynamic methods under daily illumination, to select a more accurate pupil measurement method, and to make corrections for the evaluation of preoperative biometric indexes.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Other

入排标准

年龄范围
50 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • (1) diagnosed with cataract; (2) treated with lens ultrasonic emulsification combined with monofocal IOL implantation in our hospital; (3) agreed to participate and cooperate with this study.

排除标准

  • (1) acute eye disease symptoms, such as eye redness, eye pain, increased ocular secretions, etc.; (2) other eye diseases that seriously affect visual function in both eyes, such as amblyopia, high myopia, glaucoma, diabetic retinopathy, severe age-related macular degeneration and retinal detachment, etc.; (3) intra-operative or post-operative complications in cataract surgery; combined with other ophthalmic surgeries; and any other ophthalmic surgery for both eyes in the follow-up period; the presence of any other ophthalmic surgery in both eyes in the follow-up period. (4) Inability to understand the informed consent form and inability to communicate.

结局指标

主要结局

pupil size

时间窗: 1 week, 1 month, 3 months

pupil size before and after cataract surgery

次要结局

未报告次要终点