跳至主要内容
临床试验/NCT04629066
NCT04629066已完成不适用

Efficacy and Safety of ICD Remote Monitored Exercise Testing to Improve Heart Failure Outcomes: REMOTE HF-ACTION (Pilot Randomized Controlled Trial)

Duke University2 个研究点 分布在 1 个国家目标入组 13 人开始时间: 2021年4月27日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
13
试验地点
2
主要终点
Abbott Implantable Cardioverter-defibrillator (ICD) or Cardiac Resynchronization Therapy Defibrillator (CRT-D) Device Measured Daily Physical Activity (PA)

研究概览

简要总结

This single center randomized controlled trial will involve 50 medically stable outpatients with HF, reduced ejection fraction, and previously implanted ICD or CRT-D devices followed longitudinally on the Abbott Medical Merlin remote patient monitoring network. Patients will be randomized in a 1:1 fashion to usual care plus a remotely administered home based weekly prescription for aerobic exercise (intervention) or usual care alone (control). Usual care will include regularly scheduled visits with the clinical heart failure care team and medical therapy as prescribed by that team. The exercise prescription will be created by an exercise physiologist after incorporating remotely collected data from a patient directed smartphone app assessing HF symptom severity, vital signs, weight, and blood sugar, implantable device measures of physical activity, heart rate, heart failure volume status and heart rhythm, and Fitbit measures of physical activity.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients have a MERLIN patient registry record for an ICD or CRT-D implantation between 01/01/2010-12/31/2020
  • Age > 18 years
  • Left ventricular ejection fraction < 50% by echocardiogram, nuclear cardiology scan, cardiac magnetic resonance imaging, or invasive left ventriculography within the past 12 months.
  • Ongoing NYHA class II, III, or IV HF symptoms by questionnaire
  • Ongoing use of beta-blocker and ACE-inhibitor or angiotensin receptor blocker or willingness to start them- assessed by Duke Epic EMR screening.
  • Life expectancy > 12 months
  • To allow for a post-surgical adjustment period, patients must be >30 days out from device implantation

排除标准

  • Prior participation in CR- by patient questionnaire
  • Unwillingness to sign informed consent form
  • Currently performing > 240 minutes of device detected daily PA- by ICD/CRTD remotely collected data.
  • Lack of a smartphone or unwillingness to use an App or Fitbit device
  • Prior left ventricular assist device (LVAD) implantation or heart transplantation
  • ICD tachyarrhythmia therapies programmed off
  • Inherited arrhythmia condition with contraindication to exercise (eg Lamin A mutation or ARVC)
  • No transmissions through Merlin.net in past 12 months

结局指标

主要结局

Abbott Implantable Cardioverter-defibrillator (ICD) or Cardiac Resynchronization Therapy Defibrillator (CRT-D) Device Measured Daily Physical Activity (PA)

时间窗: 12 weeks after randomization

Reported in minutes of PA per day.

次要结局

  • Change in Kansas City Cardiomyopathy Questionnaire (KCCQ) Heart Failure (HF) Symptoms Severity Score(Baseline to 12 weeks)
  • Number of Heart Failure Hospitalization, Fracture, Myocardial Infarction, Serious Adverse Arrhythmia, and ICD Therapy Combination Events(Cumulative during 12 weeks of intervention)
  • Kansas City Cardiomyopathy Questionnaire (KCCQ) Heart Failure (HF) Symptom Severity Score(12 weeks after randomization)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验